DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part MK706-85 to receive an up to date pricing and availability quote by email.
A grouping of two or more physically connected or related electrical an/or electronic parts capable of dissassemblage. Each component of the assemblage must be capable of functioning in accordance with its own item name. Consists of a single printed circuit board or terminal board upon which are mounted separately manufactured electronic components such as capacitors, inductors, resistors, and the like. It may also include printed electronic components. The item is generally part of a subassembly and cannot be assigned a more definite item name. For items having a complete individual electrical/electronic function, use applicable item name such as amplifier (as modified); power supply; or the like. For items not having a complete individual electrical/electronic function, see applicable subassembly name, such as amplifier subassembly; power supply subassembly; or the like. For an assembly of electrical/electronic components mounted on other than a single printed wiring board, see electronic components assembly. Excludes:printed circuit board
6.050 inches nominal center to center distance between mounting facilities parallel to length, 0.725 inches nominal center to center distance between mounting facilities parallel to width, 7.496 inches nominal overall length, dc circuit current for which designed, 1500.0 dielectric withstanding voltage in volts
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Circuit Current For Which Designed
- dc
- Dielectric Withstanding Voltage In Volts
- 1500.0
- Overall Length
- 7.496 inches nominal
- Center To Center Distance Between Mounting Facilities Parallel To Length
- 6.050 inches nominal
- Center To Center Distance Between Mounting Facilities Parallel To Width
- 0.725 inches nominal
- Overall Height
- 1.520 inches nominal
- Overall Width
- 6.690 inches nominal
- Mounting Hole Diameter
- 0.221 inches nominal
- Environmental Protection
- cold resistant and dripproof and heat resistant and humidity resistant and shock resistant and vibration resistant
- Furnished Items And Quantity
- washer6; nut 6
- Indicator Type
- dial w/pointer
- Installation Design
- panel
- Mounting Arrangement Style
- four hole/stud rectangular/square
- Sensitivity Rating
- 200.0 microamperes
- Dial Scale Marking Color
- black single indicator single range
- Accuracy In Percent
- -2.0 to 2.0 at full scale single indicator single range
- Meter Depth Behind Mounting Flange
- 5.760 inches nominal
- Meter Body Width Behind Mounting Flange
- 5.435 inches nominal
- Movement Type
- moving coil, permanent magnet
- Background Color
- white single indicator single range
- Pointer Color
- black single indicator single range
- Scale Marking
- line at 0 and 100 pct points
- Mounting Facility Type And Quantity
- 4 screw and 4 unthreaded hole
- Scale Graduation Type
- nonlinear single indicator single range
- Meter Body Height Behind Mounting Flange
- 1.225 inches nominal
- Features Provided
- magnetic shield and zero adjuster
- Movement Suspension Method
- jewel pivot base
- Circuit Attachment Method And Quantity
- 2 threaded stud
- Material
- plastic
- Style Designator
- rectangular flush mtg
- Supplementary Features
- 20 megohms insulation res
- Fsc Application Data
- test set, electronic equipment
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 1001-17200 | Arbitrary Scale Meter |
| MK706-85 | Arbitrary Scale Meter |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 6625-01-464-1998?
Does the NSN 6625-01-464-1998 have a Schedule B code assigned?
Does NSN 6625-01-464-1998 require demilitarization?
Does NSN 6625-01-464-1998 contain precious materials?
Does NSN 6625-01-464-1998 contain hazardous materials?
When the NSN 6625-01-464-1998 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: