6625-01-299-4535

Find complete technical information, availability, and procurement data for: 6625-01-299-4535

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-299-4535 to receive an up to date pricing and availability quote by email.

6625-01-299-4535
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-299-4535
Item Name Code
16449
Assigment Date
05/01/1989 (37 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

dc circuit current for which designed, 2.420 inches nominal overall length, 4.180 inches maximum overall height, 3.552 inches minimum and 3.572 inches maximum center to center distance between mounting facilities parallel to width, 3.990 inches minimum and 4.010 inches maximum center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
2.420 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
3.990 inches minimum and 4.010 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Width
3.552 inches minimum and 3.572 inches maximum
Overall Height
4.180 inches maximum
Overall Width
4.730 inches maximum
Scale Division Quantity
20 single indicator single range
Mounting Stud Length
0.500 inches nominal
Furnished Items And Quantity
nut 2; washer 6
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.200 inches nominal
Meter Body Diameter Behind Mounting Flange
2.700 inches maximum
Movement Type
moving iron vane
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
-10.0 to 10.0 volts, dc single indicator single range
Mounting Stud Diameter
0.112 inches nominal
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
255421MTMT Voltmeter
50-255421MTMT Voltmeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-299-4535?
The FSCG of the NSN 6625-01-299-4535 is 6625
Does the NSN 6625-01-299-4535 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-299-4535 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-299-4535 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-299-4535 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-299-4535 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Mon, May 1, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

15308-5
5930-01-172-9638
Pressure Switch
15308-6
5930-01-222-3398
Pressure Switch
15308 BLK.OXIDE
5305-00-984-3990
Machine Screw
15308 BLK.OXIDEADX
5305-00-984-3990
Machine Screw
153080
8145-01-573-2514
V Shipping and Storage Container
1530803
2815-01-580-1203
Couplingassembly
1530803-101
1680-01-506-9297
Aircra Tip Assembly
1530803-102
1560-01-374-9421
Aircraft Tip
1530811
2910-00-864-0729
Fluid Filter Element
153082
5330-00-450-0651
Rubber Strip
153083
2805-00-862-0680
Engine Crankshaft
1530831
6515-01-676-8904
Oximeter Pulse Monitoring Sensor
153084
2810-00-348-8752
Cylinder Assy
153084-100
5995-01-117-8229
Radio Frequency Cable Assembly
153084-105
5995-01-117-8232
Radio Frequency Cable Assembly