6625-01-217-7624

Find complete technical information, availability, and procurement data for: 6625-01-217-7624

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-217-7624 to receive an up to date pricing and availability quote by email.

6625-01-217-7624
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-217-7624
Item Name Code
77777
Assigment Date
10/03/1985 (40 years ago)

A substance which, by physical or chemical change, indicates that a degree of heat sufficient to effect sterilization of all items within a sterilizer has been attained.

simulator medical functions: battery op port self-contained part name assigned by controlling agency, 24.00 pounds exterior container weight, 0.1200 cubic feet unit of issue cube, item shall perform withing following climatic conditions: temperature, non-operating, -46 deg c to +70 deg c/operating, 0 deg c to 55 deg c; operating characteristics shall be as follows: blood pressure heart rate shall be 30-240 bpm, bp outputs shall be 0-200 mm hg +/- 2%, unit have selectable 120/80 hg +/- output, static and dynamic wave forms, ecg simulator shall be variable, respiration rate be variable, temperature output be selectable; unit have electrode lead continuity test feature; selector switch(s)/terminals describe function, range, test; unit furnished with protective case special features, battery operated; portable; solid state; in protective case; self contained; produces simulated physiological parameters for blood pressure; ecg waveforms; respiration; and electronic temp; operates on common type battery (not supplied); includes low voltage indicator and electrode lead continuity general characteristics item description

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Part Name Assigned By Controlling Agency
simulator medical functions: battery op port self-contained
Exterior Container Weight
24.00 pounds
Special Features
item shall perform withing following climatic conditions: temperature, non-operating, -46 deg c to +70 deg c/operating, 0 deg c to 55 deg c; operating characteristics shall be as follows: blood pressure heart rate shall be 30-240 bpm, bp outputs shall be 0-200 mm hg +/- 2%, unit have selectable 120/80 hg +/- output, static and dynamic wave forms, ecg simulator shall be variable, respiration rate be variable, temperature output be selectable; unit have electrode lead continuity test feature; selector switch(s)/terminals describe function, range, test; unit furnished with protective case
Unit Of Issue Cube
0.1200 cubic feet
General Characteristics Item Description
battery operated; portable; solid state; in protective case; self contained; produces simulated physiological parameters for blood pressure; ecg waveforms; respiration; and electronic temp; operates on common type battery (not supplied); includes low voltage indicator and electrode lead continuity

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
215A (MODIFIED) Medical Functions Simulator
5-635 Medical Functions Simulator
MEDSIM 300B Medical Functions Simulator

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-217-7624?
The FSCG of the NSN 6625-01-217-7624 is 6625
Does NSN 6625-01-217-7624 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-217-7624 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-217-7624 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-217-7624 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Thu, Oct 3, 1985

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

108592-01
5962-01-096-2199
Digital Microcircuit
1085925
5999-01-706-5218
Electronic Equipme Accessory Kit
108593
5360-00-260-6666
Compression Helical Spring
1085930
4820-00-083-3126
Calibrated Flow Valve
1085930-2
4820-00-083-3112
Flow Control Valve
1085930-3
4820-00-083-3113
Check Valve
1085930-4
4820-00-083-3114
Flow Control Valve
1085930-5
4820-00-083-3124
Calibrated Flow Valve
1085930-6
4820-00-557-0116
Restrictor Check Valve
1085930-7
4820-00-083-3126
Calibrated Flow Valve
1085939A
5970-01-054-6958
Plate Insulator
108594-01
5962-01-213-8156
Digital Microcircuit
1085941
4330-01-674-3520
Fluid Filter Body
1085945-4
5365-00-073-3688
Plate Spacer
1085946
5945-00-834-9097
Electromagnetic Relay