MR26W001DCKAR

View detailed technical data, stock status, and sourcing information for: MR26W001DCKAR

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part MR26W001DCKAR to receive an up to date pricing and availability quote by email.

MR26W001DCKAR
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-169-6524
Item Name Code
16450
Assigment Date
04/03/1968 (58 years ago)

50 single indicator single range scale division quantity, 2.650 inches maximum overall length, dc circuit current for which designed, 0.125 inches nominal mounting hole diameter, 2.695 inches maximum overall diameter

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
2.650 inches maximum
Mounting Hole Diameter
0.125 inches nominal
Scale Division Quantity
50 single indicator single range
Overall Diameter
2.695 inches maximum
Environmental Protection
airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Mounting Bolt Circle Diameter
2.440 inches nominal
Furnished Items And Quantity
nut 7; lockwasher 5; seal 1
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
three hole/stud bolt circle
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.600 inches maximum
Meter Body Diameter Behind Mounting Flange
2.210 inches maximum
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 1.0 kiloamperes, dc single indicator single range
Scale Selection Method
switch
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Special Features
ruggedized
Material
steel
Surface Treatment
paint
Style Designator
round flush mtg
Test Data Document
"81349-mil-prf-10304 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Specification/Standard Data
81349-mil-prf-10304/5 government specification
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
MR26W001DCKAR Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-169-6524?
The FSCG of the NSN 6625-00-169-6524 is 6625
Does the NSN 6625-00-169-6524 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-169-6524 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-169-6524 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-169-6524 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-169-6524 was assigned to the Federal Catalog?
It was assigned 58 years ago, on Wed, Apr 3, 1968

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

C10988-7
6150-01-185-1862
E Special Purpose Cable Assembly
C109881
5365-01-149-6272
Shim Set
C10989-1
6145-01-229-8302
Electrical Special Purpose Cable
C1098B-62
5950-01-131-3540
Coil
C1098PC84
5331-00-286-0093
O-Ring
C1099-30
5935-00-811-3257
Electrical Plug Connector
C1099-62004
7025-01-526-3130
Data Entry Keyboard
C10990-12-50SN
5935-01-195-2019
Electrical Plug Connector
C10990-19-50SN
5935-01-179-3373
Electrical Plug Connector
C10990-27-50PN
5935-01-183-9656
Electrical Plug Connector
C10990-27-50SN
5935-01-183-6712
Electrical Plug Connector
C10990-3-50SN
5935-01-187-7982
Electrical Plug Connector
C10990-37-50PN
5935-01-183-6713
Electrical Plug Connector
C109902
5330-01-308-1186
Plain Encased Seal
C10991-1
5985-01-260-7842
Electrical Dummy Load