1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-01-334-1391

5950-01-334-1391

Find complete technical information, availability, and procurement data for: 5950-01-334-1391

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-01-334-1391 to receive an up to date pricing and availability quote by email.

5950-01-334-1391
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-334-1391
Item Name Code
32496
Assigment Date
02/16/1991 (35 years ago)

A panel mounted dual function control, three way valve which incorporates a check valve to protect the emergency supply reservoir and to control the supply and exhaust ports.

75.0 volt-ampere single component maximum transformer power rating, single phase to single phase single component input-output phase relationship, vibration resistant hazardous locations/environmental protection, not established reliability indicator, 400.0 hertz nominal single component frequency rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Hazardous Locations/Environmental Protection
vibration resistant
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Maximum Transformer Power Rating
75.0 volt-ampere single component
Body Length
1.969 inches minimum and 2.031 inches maximum
Overall Diameter
2.219 inches minimum and 2.281 inches maximum
Maximum Operating Temp
130.0 celsius
Mounting Bolt Circle Diameter
1.750 inches nominal single mounting facility single center group
Inclosure Type
hermetically sealed
Mounting Facility Quantity
3 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 1 secondary single component
Nominal Thread Size
0.164 inches single group
Winding Operating Current
8.33 amperes ac nominal single component single secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
12.00 ac volts nominal single component single secondary
Test Data Document
"81349-mil-prf-27 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc single group
Terminal Type And Quantity
5 feed thru
Specification/Standard Data
81349-mil-prf-27/59 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M27/59-01 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-334-1391?
The FSCG of the NSN 5950-01-334-1391 is 5950
Does the NSN 5950-01-334-1391 have a Schedule B code assigned?
Yes, the Schedule B code is 8504314065
Does NSN 5950-01-334-1391 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-334-1391 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-334-1391 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-334-1391 was assigned to the Federal Catalog?
It was assigned 35 years ago, on Sat, Feb 16, 1991

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

17P2D1044-503
4730-01-361-8162
Tube Tee
17P2D1044-505
4730-01-361-8163
Tube Tee
17P2D1045-1
4710-01-361-4043
Metal Tube Assembly
17P2D1046-1
1560-01-361-4046
Airframe Fabricated Fuel Line
17P2D1047-1
1560-01-361-4044
Airframe Fabricated Fuel Line
17P2D1048-1
1560-01-361-4045
Airframe Fabricated Fuel Line
17P2D1049
4710-01-444-0176
Metallic Tube and Fittings
17P2D1049-1
4710-01-444-0176
Metallic Tube and Fittings
17P2D1066-1
2915-01-360-2984
Fuel Control Housing
17P2D1067-1
5325-01-360-6766
Retaining Ring
17P2D1071
4730-01-361-3920
Tube to Boss Tee
17P2D1071-1
4730-01-361-3920
Tube to Boss Tee
17P2D1074-501
4730-01-377-3447
Tube Nipple
17P2D1077
4710-01-390-7973
Metal Tube Assembly
17P2D1077-1
4710-01-390-7973
Metal Tube Assembly