MIL-T-27/66

View detailed technical data, stock status, and sourcing information for: MIL-T-27/66

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part MIL-T-27/66 to receive an up to date pricing and availability quote by email.

MIL-T-27/66
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-115-0252
Item Name Code
32496
Assigment Date
06/26/1981 (45 years ago)

2.250 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, not established reliability indicator, 2.250 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, vibration resistant hazardous locations/environmental protection, 400.0 hertz nominal single component frequency rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Hazardous Locations/Environmental Protection
vibration resistant
Center To Center Distance Between Mounting Facilities Parallel To Length
2.250 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.250 inches nominal single mounting facility single center group
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Maximum Transformer Power Rating
250.0 volt-ampere single component
Winding Shielding Method
internal shield brought out to terminal single component
Body Length
1.969 inches minimum and 2.031 inches maximum
Body Outside Diameter
2.844 inches minimum and 2.906 inches maximum
Maximum Operating Temp
130.0 celsius
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 1 secondary single component
Nominal Thread Size
0.164 inches single group
Winding Operating Current
2.17 amperes ac nominal single component single secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
115.00 ac volts nominal single component single secondary
Test Data Document
"81349-mil-t-27 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc single group
Terminal Type And Quantity
6 feed thru
Specification/Standard Data
81349-mil-t-27/66 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M27/66-18 Power Transformer
MIL-PRF-27/66 Power Transformer
MIL-T-27/66 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-115-0252?
The FSCG of the NSN 5950-01-115-0252 is 5950
Does the NSN 5950-01-115-0252 have a Schedule B code assigned?
Yes, the Schedule B code is 8504314065
Does NSN 5950-01-115-0252 require demilitarization?
Usml items - mutilation to the point of scrap required worldwide. (note 7).
Does NSN 5950-01-115-0252 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-115-0252 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-115-0252 was assigned to the Federal Catalog?
It was assigned 45 years ago, on Fri, Jun 26, 1981

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

AES14U312A50BB3A81
5305-01-700-2865
Socket Head Cap Screw
AES14U312A50BB3A86
5305-01-700-3042
Socket Head Cap Screw
AES14U312A50BB3QW1
5305-01-702-2209
Socket Head Cap Screw
AES14U312A75AA9A11
5305-01-671-0916
Socket Head Cap Screw
AES14U312B25AA9A11
5305-01-671-0917
Socket Head Cap Screw
AES14U312B75BB3L71
5305-01-675-3828
Hexagon Head Cap Screw
AES14U312C25WA6FQ1
5305-01-673-5540
Socket Head Cap Screw
AES14U312D50BB3MF1
5305-01-678-7221
Socket Head Cap Screw
AES14U312E00BB3L71
5305-01-675-9189
Socket Head Cap Screw
AES14U375750BB3A81
5305-01-700-3046
Socket Head Cap Screw
AES14U375750BB3QW1
5305-01-702-2210
Socket Head Cap Screw
AES14U375875BB3A81
5305-01-700-3050
Socket Head Cap Screw
AES14U375875BB3QW1
5305-01-702-2211
Socket Head Cap Screw
AES14U375A00BB3A81
5305-01-700-3059
Socket Head Cap Screw
AES14U375A00BB3QW1
5305-01-702-2212
Socket Head Cap Screw