1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-944-2861

5950-00-944-2861

Find complete technical information, availability, and procurement data for: 5950-00-944-2861

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-944-2861 to receive an up to date pricing and availability quote by email.

5950-00-944-2861
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-944-2861
Item Name Code
32496
Assigment Date
02/18/1966 (60 years ago)

A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes:saturable reactor. For reactors with air cores, see coil (as modified).

2.110 inches minimum and 2.130 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to width, 3.110 inches minimum and 3.130 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to length, 380.0 hertz minimum and 420.0 hertz maximum single component frequency rating, not established reliability indicator, three phase to single phase single component input-output phase relationship

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
3.110 inches minimum and 3.130 inches maximum single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.110 inches minimum and 2.130 inches maximum single mounting facility single center group
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
Input-Output Phase Relationship
three phase to single phase single component
Transformer Winding Connection Type
wye-wye
Maximum Transformer Power Rating
28.1 volt-ampere single component
Body Length
3.880 inches maximum
Body Width
2.620 inches maximum
Body Height
1.750 inches maximum
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded hole single group
Winding Function And Quantity
1 primary and 6 secondary single component
Nominal Thread Size
0.138 inches single group
Winding Operating Current
23.0 milliamperes ac nominal single component 4th secondary
Winding Operating Current
25.0 milliamperes ac nominal single component 3rd secondary
Winding Operating Current
17.0 milliamperes ac nominal single component 1st secondary
Winding Operating Current
600.0 milliamperes ac nominal single component 2nd secondary
Winding Power Rating
15.6 volts-amperes single component 2nd secondary
Winding Power Rating
2.25 volts-amperes single component 4th secondary
Winding Power Rating
2.5 volts-amperes single component 1st secondary
Winding Power Rating
0.75 volts-amperes single component 3rd secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
26.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
30.00 ac volts nominal single component 3rd secondary
Winding Operating Voltage
36.00 ac volts nominal and 144.00 ac volts nominal single component 1st secondary
Winding Operating Voltage
25.00 ac volts nominal and 75.00 ac volts nominal and 100.00 ac volts nominal single component 4th secondary
Special Features
one primary winding; six secondary windings with 3rd and 6th windings center tapped and 1st and 4th windings multiple tapped w/center tap
Thread Series Designator
unc single group
Terminal Type And Quantity
24 turret

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
160801 Power Transformer
927C890-1 Power Transformer
9T33Y6611 Power Transformer
T61589 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-944-2861?
The FSCG of the NSN 5950-00-944-2861 is 5950
Does the NSN 5950-00-944-2861 have a Schedule B code assigned?
Yes, the Schedule B code is 8504314035
Does NSN 5950-00-944-2861 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-944-2861 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-944-2861 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-944-2861 was assigned to the Federal Catalog?
It was assigned 60 years ago, on Fri, Feb 18, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RP2200-F03
5975-01-118-8369
Electrical Conduit Coupling
RP2200-F05
5975-01-118-8371
Electrical Conduit Coupling
RP2200-F06
5975-01-119-9337
Electrical Conduit Coupling
RP2200-G03
5975-01-118-8369
Electrical Conduit Coupling
RP2200-G05
5975-01-118-8371
Electrical Conduit Coupling
RP2200-G06
5365-01-119-9937
Ring Spacer
RP2210-EM06
5975-01-118-6760
Electrical Conduit Coupling
RP2210-EM08
5975-01-118-6761
Electrical Conduit Coupling
RP2210-G06
5975-01-118-6760
Electrical Conduit Coupling
RP2210-G08
5975-01-118-6761
Electrical Conduit Coupling
RP2210-S06
5975-01-118-6760
Electrical Conduit Coupling
RP2210-S08
5975-01-118-6761
Electrical Conduit Coupling
RP22135D
5950-00-815-9589
Power Transformer
RP222-3
1680-01-074-2364
Mecha Seal Replacement Parts Kit
RP224
5310-01-668-3812
Flat Washer