1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-188-7446

5950-00-188-7446

Find complete technical information, availability, and procurement data for: 5950-00-188-7446

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-188-7446 to receive an up to date pricing and availability quote by email.

5950-00-188-7446
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-188-7446
Item Name Code
32496
Assigment Date
01/01/1963 (63 years ago)

0.193 inches nominal single group mounting hole diameter, not established reliability indicator, 2.125 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 2.562 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 50.0 hertz minimum and 1.2 kilohertz maximum single component frequency rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.562 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.125 inches nominal single mounting facility single center group
Mounting Hole Diameter
0.193 inches nominal single group
Frequency Rating
50.0 hertz minimum and 1.2 kilohertz maximum single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to core and brought out to terminal single component
Body Length
3.703 inches nominal
Body Width
3.250 inches nominal
Body Height
3.453 inches nominal
Inclosure Type
partially inclosed, double shell
Mounting Facility Quantity
4 single group
Mounting Method
flange and unthreaded hole single group
Winding Function And Quantity
1 primary and 4 secondary single component
Winding Operating Current
1.25 amperes ac maximum single component 1st secondary
Winding Operating Current
1.7 amperes ac maximum single component 3rd secondary
Winding Operating Current
2.0 amperes ac maximum single component 2nd secondary
Winding Operating Current
29.0 milliamperes ac maximum single component 4th secondary
Winding Operating Voltage
1.70 ac kilovolts nominal single component 4th secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
6.30 ac volts nominal single component 1st secondary
Winding Operating Voltage
6.30 ac volts nominal single component 3rd secondary
Winding Operating Voltage
5.00 ac volts nominal single component 2nd secondary
Terminal Type And Quantity
12 tab, solder lug

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5950-00-243-5129 No Name Available 03/08/1968

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5660263 Power Transformer
56602630LD Power Transformer
660263C Power Transformer
RB1660 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-188-7446?
The FSCG of the NSN 5950-00-188-7446 is 5950
Does NSN 5950-00-188-7446 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-188-7446 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-188-7446 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-188-7446 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

95-0293
6505-01-413-0497
Atropine Sulfate Tablets
95-02933
4920-00-919-1645
Aircraft Maintenance Adapter Set
95-03-009
9905-00-148-9546
Tr Highway Warning Reflector Set
95-03-03-009 AT
6515-01-411-1508
Multifunctional Electrode Pad
95-0307
6515-01-414-1828
Cryosurgical Probe
95-0310
6540-01-413-9101
Ophthalmic Lens Generator
95-0313
6505-01-414-1864
Strong Iodine Solution
95-0314
6505-01-287-0626
Sodium Chloride Injection
95-0315
6505-01-287-0627
Sterile Water for Injection
95-0317
6505-01-199-8359
Magnesium Sulfate Injection
95-0319
6550-01-317-4927
Formaldehyde Solution
95-0320
6505-01-414-3705
Podophyllum Resin Topical Soluti
95-0322
6515-01-243-0536
Bone Fixation Wire Tightener
95-0323
6630-01-415-1588
Generator Cartridge Assembly
95-0325
6515-01-420-9261
Artificial Mastoid