1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-226-3586

5925-01-226-3586

Find complete technical information, availability, and procurement data for: 5925-01-226-3586

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-226-3586 to receive an up to date pricing and availability quote by email.

5925-01-226-3586
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-226-3586
Item Name Code
00136
Assigment Date
02/15/1986 (40 years ago)

5.125 inches nominal center to center distance between terminals parallel to length, 3.000 inches nominal body height, 3.000 inches nominal body width, multipole-single actuator type body style, 6.000 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.000 inches nominal
Body Width
3.000 inches nominal
Body Height
3.000 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.125 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.500 inches nominal
Unthreaded Mounting Hole Diameter
0.203 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.125 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
Boss Height
0.125 inches nominal
Pole Quantity
2
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
20000.0 ac and 10000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct and 125.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
FAL24020 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-226-3586?
The FSCG of the NSN 5925-01-226-3586 is 5925
Does the NSN 5925-01-226-3586 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-226-3586 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-226-3586 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-226-3586 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-226-3586 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Sat, Feb 15, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

5925-055
2540-01-623-8679
Vehicular Seat Cushion
5925-058
5365-01-623-5714
Plate Spacer
5925-077
2090-01-623-8683
Ship Chair Armrest
5925-09
4330-01-606-5442
Fluid Filter Element
5925-094
5340-01-623-4023
Manual Control Handle
5925 1/2-INCH
7510-01-623-7012
Pressure Sensitive Adhesive Tape
5925-105-10-01
5925-01-618-6643
Circuit Breaker
5925-151
2090-01-623-8694
Ship Chair Armrest
5925-152
2090-01-623-4021
Ship Chair Armrest
5925-2
5925-00-320-7673
Circuit Breaker
5925-243
5340-01-623-3959
Mechanical Stop
5925.528.11
5945-01-475-4353
Electromagnetic Relay
5925.570.6
5945-01-429-9160
Thermal Relay
5925-571-7
4130-01-133-0300
Overload
5925-573-6AND5945-657-1
6110-00-246-3109
Elect Thermal-Overload Protector