1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-200-7812

5925-01-200-7812

Find complete technical information, availability, and procurement data for: 5925-01-200-7812

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-200-7812 to receive an up to date pricing and availability quote by email.

5925-01-200-7812
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-200-7812
Item Name Code
00136
Assigment Date
02/09/1985 (41 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

3.546 inches nominal center to center distance between terminals parallel to length, 0.164 inches nominal mounting slot width, 3.544 inches nominal body length, multipole-multiple actuator type body style, 4.128 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Mounting Slot Width
0.164 inches nominal
Body Length
3.544 inches nominal
Body Width
4.128 inches nominal
Center To Center Distance Between Terminals Parallel To Length
3.546 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.032 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches nominal
Boss Height
0.218 inches nominal
Mounting Surface To Terminal End Distance
2.609 inches nominal
Pole Quantity
4
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
8 threaded hole and 8 slot
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
0.0 amperes ac fourth location
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac fourth location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, three, and four linked
Internal Trip Release Configuration
series trip first location
Internal Trip Release Configuration
series trip second location
Internal Trip Release Configuration
series trip third location
Internal Trip Release Configuration
shunt trip fourth location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.530 minimum at 200 pct and 1.500 maximum at 200 pct fourth location
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct and 105.000 maximum at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct and 105.000 maximum at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct and 105.000 maximum at 200 pct third location
Inclosure Protection Type For Which Designed
dustproof
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
9 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5050213-2 Circuit Breaker
CD4-Z132-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-200-7812?
The FSCG of the NSN 5925-01-200-7812 is 5925
Does the NSN 5925-01-200-7812 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-200-7812 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-200-7812 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-200-7812 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-200-7812 was assigned to the Federal Catalog?
It was assigned 41 years ago, on Sat, Feb 9, 1985

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

37W26020-12
1560-00-534-2332
Ailer Seal Retainer
37W26020-9
1560-00-534-2375
Ailer Seal Retainer
37W26021-1
1560-00-532-1259
Aircraft Fairing
37W26021-2
1560-00-532-1260
Aircraft Fairing
37W26021-4
1560-00-532-1262
Aircraft Fairing
37W2SECT1000/100OHM
5905-00-259-3917
Resistor,variable,nonwire Wound,
37W32112-1
3120-00-662-6240
Sleeve Bearing
37W32112-3
3120-00-517-9087
Sleeve Bearing
37W32115-1
1560-00-567-0862
Aileron Cont Collar
37W32119-1
5365-00-576-1849
Shim
37W32137-1
3040-00-532-1263
Shouldered Shaft
37W32138-1
1560-00-506-7129
Wing Root Ai Block
37W32531-1
3040-00-320-6417
Rigid Connecting Link
37W38014-2
1560-00-567-0888
M Fairlead Assembly
37W38113-1
1650-00-692-2394
Linear Actuating Cylinder Piston