1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-090-5257

5925-01-090-5257

Find complete technical information, availability, and procurement data for: 5925-01-090-5257

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-090-5257 to receive an up to date pricing and availability quote by email.

5925-01-090-5257
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-090-5257
Item Name Code
00136
Assigment Date
02/21/1980 (46 years ago)

An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes:filter (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see transformer, radio frequency. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see suppressor, parasitic.

2.046 inches minimum and 2.078 inches maximum distance between centerlines of mounting facilities parallel to body length, 0.730 inches minimum and 0.780 inches maximum body width, 1.660 inches minimum and 1.960 inches maximum center to center distance between terminals parallel to length, single pole type body style, 2.510 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.510 inches maximum
Body Width
0.730 inches minimum and 0.780 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Boss Height
0.109 inches minimum and 0.171 inches maximum
Mounting Surface To Terminal End Distance
2.800 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 1.900 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
400.0 single location
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud
Specification/Standard Data
81349-mil-c-55629/2 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-097-8071 No Name Available 12/01/2000

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M55629/2-027 Circuit Breaker
SMB650868 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-090-5257?
The FSCG of the NSN 5925-01-090-5257 is 5925
Does the NSN 5925-01-090-5257 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-090-5257 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-090-5257 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-090-5257 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-090-5257 was assigned to the Federal Catalog?
It was assigned 46 years ago, on Thu, Feb 21, 1980

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

33-1267878-8
5930-01-244-4626
Push Switch
33-1267878-9
5930-01-244-3348
Push Switch
33.127
3455-00-224-8925
Rotary File
33.127REV B 1-2IN
4820-00-590-8770
Globe Valve
33-128
5935-00-923-4138
Tip Plug
33-128-BU
5935-01-364-3627
Tip Plug
33-128RED
5935-00-923-4138
Tip Plug
33-129
5120-01-335-0615
Drift Punch
33-1290
6515-01-139-8204
Kidney Pedicle Forceps
33-129038-1
5930-00-801-2775
Toggle Switch
33-12B
5355-00-871-6025
Knob
33-12N6394
2825-00-524-0788
Overspeed Rotor Assy
33-12R
5355-00-135-5212
Knob
33.130
3455-00-953-1273
Rotary File
33-130-BU
5935-00-923-4137
Tip Plug