1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-069-2201

5925-01-069-2201

Find complete technical information, availability, and procurement data for: 5925-01-069-2201

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-069-2201 to receive an up to date pricing and availability quote by email.

5925-01-069-2201
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-069-2201
Item Name Code
00136
Assigment Date
12/10/1978 (47 years ago)

1.928 inches minimum and 1.948 inches maximum center to center distance between terminals parallel to length, 2.052 inches minimum and 2.072 inches maximum distance between centerlines of mounting facilities parallel to body length, 2.490 inches minimum and 2.510 inches maximum body length, 0.740 inches minimum and 0.760 inches maximum body width, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.490 inches minimum and 2.510 inches maximum
Body Width
0.740 inches minimum and 0.760 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.130 inches minimum and 0.150 inches maximum
Mounting Surface To Terminal End Distance
2.611 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
instantaneous single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
0.088 nominal single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Unpackaged Unit Weight
4.250 ounces nominal
Frequency In Hertz
50.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM1-A3-20-P Circuit Breaker
UPL1-1-69-203 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-069-2201?
The FSCG of the NSN 5925-01-069-2201 is 5925
Does the NSN 5925-01-069-2201 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-069-2201 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-069-2201 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-069-2201 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-069-2201 was assigned to the Federal Catalog?
It was assigned 47 years ago, on Sun, Dec 10, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

T70HFL40S02
5961-01-328-0388
Diode Semiconductor Device
T70HFL60S02
5961-01-301-6733
Semiconductor Device Rectifier
T70ICIW
5975-01-632-8816
Raceway Coupler
T70L5D131-5
5945-01-377-2380
Electromagnetic Relay
T70L5D164-24
5945-01-413-1282
Electromagnetic Relay
T70OCIW
5975-01-632-8811
Electrical Conduit Tee
T70P3-P0330
5895-01-548-8433
Electrical-Electro Control Panel
T70P3Z-9.5
5895-01-528-7564
Data Entry Trackball
T70R62
5950-00-194-2320
Power Transformer
T70RAIW
5975-01-632-8714
Raceway Coupler
T70RAWH
5975-01-621-9764
Raceway Coupler
T70RIA60
5961-01-523-1532
Thyristor Semiconductor Device
T70T2
5950-00-451-4217
Power Transformer
T70TIW
5975-01-632-8812
Electrical Conduit Tee
T70TRCIW
5975-01-685-7480
Nonmetallic Raceway