UPL1-2027-4-25ADELAY62

View detailed technical data, stock status, and sourcing information for: UPL1-2027-4-25ADELAY62

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part UPL1-2027-4-25ADELAY62 to receive an up to date pricing and availability quote by email.

UPL1-2027-4-25ADELAY62
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-064-6805
Item Name Code
00136
Assigment Date
08/30/1978 (47 years ago)

0.750 inches maximum body width, single pole type body style, 2.060 inches nominal distance between centerlines of mounting facilities parallel to body length, 1.940 inches nominal center to center distance between terminals parallel to length, 2.490 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.490 inches nominal
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
Boss Height
0.150 inches nominal
Mounting Surface To Terminal End Distance
2.475 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 minimum at 150 pct and 30.000 maximum at 150 pct single location
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
A16582-004 Circuit Breaker
A16582-4 Circuit Breaker
IELK1-1-62-25.0-01-V Circuit Breaker
UPL1-2027-4 Circuit Breaker
UPL1-2027-4-25ADELAY62 Circuit Breaker
UPL1-2027-4-25AMPSDELAY62 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-064-6805?
The FSCG of the NSN 5925-01-064-6805 is 5925
Does the NSN 5925-01-064-6805 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-064-6805 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-064-6805 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-064-6805 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-064-6805 was assigned to the Federal Catalog?
It was assigned 47 years ago, on Wed, Aug 30, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

USGS 24K33612
7643-01-637-1495
Topographic Geospatial Products
USGS 24K33613
7643-01-638-7019
Topographic Geospatial Products
USGS 24K33614
7643-01-638-7871
Topographic Geospatial Products
USGS 24K33615
7643-01-636-5630
Topographic Geospatial Products
USGS 24K33616
7643-01-636-7532
Topographic Geospatial Products
USGS 24K33617
7643-01-636-7529
Topographic Geospatial Products
USGS 24K33618
7643-01-636-7534
Topographic Geospatial Products
USGS 24K33619
7643-01-637-0375
Topographic Geospatial Products
USGS 24K3362
7643-01-640-0516
Topographic Geospatial Products
USGS 24K33620
7643-01-640-5570
Topographic Geospatial Products
USGS 24K33621
7643-01-638-0371
Topographic Geospatial Products
USGS 24K33622
7643-01-636-0955
Topographic Geospatial Products
USGS 24K33623
7643-01-638-0375
Topographic Geospatial Products
USGS 24K33624
7643-01-637-7539
Topographic Geospatial Products
USGS 24K33625
7643-01-638-0367
Topographic Geospatial Products