1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-031-0663

5925-01-031-0663

Find complete technical information, availability, and procurement data for: 5925-01-031-0663

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-031-0663 to receive an up to date pricing and availability quote by email.

5925-01-031-0663
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-031-0663
Item Name Code
00136
Assigment Date
11/18/1976 (49 years ago)

single pole type body style, 0.750 inches nominal body width, 2.500 inches nominal body length, 1.938 inches nominal center to center distance between terminals parallel to length, 2.062 inches nominal distance between centerlines of mounting facilities parallel to body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.611 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.250 minimum at 200 pct and 1.200 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM12MG6-7-5-125-5-60 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-031-0663?
The FSCG of the NSN 5925-01-031-0663 is 5925
Does the NSN 5925-01-031-0663 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-031-0663 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-031-0663 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-031-0663 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-031-0663 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Thu, Nov 18, 1976

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

SEM-2161752
5975-00-296-4093
Stuffing Tube
SEM-216505Z
5330-00-202-2585
Packing Assembly
SEM-216513Z
5330-00-202-2586
Packing Assembly
SEM-216545Z
5330-00-202-2589
Packing Assembly
SEM 2226CC
4540-01-580-0660
Paper Shredder
SEM-647
7490-01-441-0134
Shredding Machine Oil
SEM 754BAG2MIL
8105-01-399-4813
Waste Receptacle Bag
SEM 755BAG3MIL
8105-01-399-4814
Waste Receptacle Bag
SEM-A-233
5935-01-346-4114
Electrica Modular Plug Connector
SEM-A-244
5935-01-193-5151
Electrical Plug Connector
SEM-A-255
5935-01-275-7219
Electrical Plug Connector
SEM-Y-0005
5935-01-239-1986
Electrical Receptacle Connector
SEM0005
5935-01-239-1986
Electrical Receptacle Connector
SEM020
5945-01-440-0628
Electromagnetic Relay
SEM09000-600
7050-01-316-2081
Analog to Digital Converter