DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-025-9612 to receive an up to date pricing and availability quote by email.

5925-01-025-9612
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-025-9612
Item Name Code
00136
Assigment Date
08/12/1976 (49 years ago)

1.655 inches minimum and 1.665 inches maximum distance between centerlines of mounting facilities parallel to body length, 1.555 inches minimum and 1.565 inches maximum center to center distance between terminals parallel to length, 1.985 inches minimum and 2.015 inches maximum body length, single pole type body style, 0.745 inches minimum and 0.755 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
1.985 inches minimum and 2.015 inches maximum
Body Width
0.745 inches minimum and 0.755 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.125 inches minimum and 0.135 inches maximum
Mounting Surface To Terminal End Distance
1.875 inches minimum and 1.885 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
instantaneous single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Unpackaged Unit Weight
2.500 ounces nominal
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
JA1-A3-20-P Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-025-9612?
The FSCG of the NSN 5925-01-025-9612 is 5925
Does the NSN 5925-01-025-9612 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-025-9612 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-025-9612 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-025-9612 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-025-9612 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Thu, Aug 12, 1976

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

10B1166
5841-00-855-0790
Transformer Grid
10B1167
5841-00-855-0767
Crystal Diode Assy
10B1170
5950-00-126-0704
Power Transformer
10B11775
3120-00-857-2325
Sleeve Bearing
10B1198
5950-00-798-1541
Power Autotransforme Transformer
10B120-1300/600-0
5915-01-160-8175
Band Pass Filter
10B120-865/530-0
5915-01-159-6023
Band Pass Filter
10B1200
5950-00-943-0080
Power Autotransforme Transformer
10B120V50-60C
5950-00-906-0716
Power Transformer
10B1214
5950-00-426-3647
Power Autotransforme Transformer
10B1218
5950-00-490-8814
Power Autotransforme Transformer
10B1220B
5950-00-153-4465
Power Autotransforme Transformer
10B1227
5950-00-909-7956
Power Autotransforme Transformer
10B1233
5950-00-458-3778
Power Transformer
10B1234
5950-00-256-8954
Power Autotransforme Transformer