5925-01-019-9696
Find complete technical information, availability, and procurement data for: 5925-01-019-9696
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-019-9696 to receive an up to date pricing and availability quote by email.
"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."
1.469 inches nominal body width, single pole type body style, 2.640 inches nominal body height, 3.219 inches nominal body length, 0.164 inches nominal mounting slot width
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- single pole type
- Mounting Slot Width
- 0.164 inches nominal
- Body Length
- 3.219 inches nominal
- Body Width
- 1.469 inches nominal
- Body Height
- 2.640 inches nominal
- Center To Center Distance Between Terminals Parallel To Length
- 2.500 inches nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 1.312 inches nominal
- Boss Height
- 0.125 inches nominal
- Pole Quantity
- 1
- Mounting Facility Type And Quantity
- 2 slot
- Maximum Continuous Load Current Rating Per Pole
- 4.75 amperes ac single location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac single location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1500.0 ac single location
- Circuit Protection Type
- overcurrent single location
- Trip Release Method
- magnetic single location
- Trip Release Characteristic
- time delay single location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 single location
- Ultimate Trip Time Per Pole In Seconds
- 105.000 minimum and 150.000 maximum single location
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 1 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at pole one
- Internal Trip Release Configuration
- relay trip single location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 175.000 minimum at 125 pct and 600.000 maximum at 125 pct and 100.000 minimum at 150 pct and 300.000 maximum at 150 pct and 40.000 minimum at 200 pct and 140.000 maximum at 200 pct and 20.000 minimum at 300 pct and 50.000 maximum at 300 pct and 6.500 minimum at 400 pct and 10.750 maximum at 400 pct and 4.000 minimum at 500 pct and 10.000 maximum at 500 pct and 0.030 minimum at 1000 pct and 0.080 maximum at 1000 pct single location
- Special Features
- shock/vibration resistant 15 g shock,10 g vibration
- Frequency In Hertz
- 60.0 single location
- Material
- plastic case
- Terminal Type And Quantity
- 1 threaded stud and 2 screw
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 8131RTV | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-01-019-9696?
Does the NSN 5925-01-019-9696 have a Schedule B code assigned?
Does NSN 5925-01-019-9696 require demilitarization?
Does NSN 5925-01-019-9696 contain precious materials?
Does NSN 5925-01-019-9696 contain hazardous materials?
When the NSN 5925-01-019-9696 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing