1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-874-0172

5925-00-874-0172

Find complete technical information, availability, and procurement data for: 5925-00-874-0172

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-874-0172 to receive an up to date pricing and availability quote by email.

5925-00-874-0172
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-874-0172
Item Name Code
00136
Assigment Date
11/17/1967 (58 years ago)

0.380 inches nominal bushing length, 1.622 inches nominal body length, 0.625 inches nominal body width, 0.906 inches nominal center to center distance between terminals parallel to length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.380 inches nominal
Body Length
1.622 inches nominal
Body Width
0.625 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
Switch Contact Arrangement
single pole, double throw
Mounting Surface To Terminal End Distance
1.656 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
250.0 milliamperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
instantaneous single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Ultimate Trip Time Per Pole In Seconds
0.005 nominal single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 control
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Switch Location And Position Designation
internal at pole one
Inclosure Protection Type For Which Designed
hermetically sealed
Switch Terminal Type
wire hook
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
Frequency In Hertz
60.0 single location
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
2282221-17 Circuit Breaker
L505001057 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-874-0172?
The FSCG of the NSN 5925-00-874-0172 is 5925
Does the NSN 5925-00-874-0172 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-874-0172 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-874-0172 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-874-0172 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-874-0172 was assigned to the Federal Catalog?
It was assigned 58 years ago, on Fri, Nov 17, 1967

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

845001A0072-1
6150-01-255-8926
Electrical Power Cable Assembly
845001A0072-2
6150-01-255-8925
Electrical Power Cable Assembly
845001A0077
6220-01-238-4325
Warning Light
845001A0079
6220-01-238-6991
Clearance Marker Light
845001A0080
6230-01-238-4323
Electric Floodlight
845001A0082
5340-00-185-6634
Snap Hook
845001A0086
6230-01-238-4384
Lamp Support
845001A0091
6160-01-238-3047
Battery Retainer
845001A0092
5306-01-240-8895
Hook Bolt
845001A0093
3040-01-239-8902
Extension Shaft
845001A0103
6130-01-238-6825
Battery Charger
845001A0104-1
6250-01-241-2318
Lamp Ballast
845001A0104-2
6250-01-238-7093
Lamp Ballast
845001A0104-3
6250-01-242-8374
Lamp Ballast
8450026
6610-01-424-6927
Position Indicator