DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-845-6612 to receive an up to date pricing and availability quote by email.

5925-00-845-6612
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-845-6612
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

single pole type body style, 0.567 inches minimum and 0.629 inches maximum body width, 1.448 inches minimum and 1.510 inches maximum body length, 0.870 inches minimum and 0.880 inches maximum center to center distance between terminals parallel to length, 0.360 inches minimum and 0.380 inches maximum bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.360 inches minimum and 0.380 inches maximum
Body Length
1.448 inches minimum and 1.510 inches maximum
Body Width
0.567 inches minimum and 0.629 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.524 inches minimum and 1.586 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Features Provided
key interlock
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
750.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 minimum at 125 pct and 4.000 maximum at 125 pct single location
Inclosure Protection Type For Which Designed
dustproof and fungus resistant
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
9157095 Circuit Breaker
SM3-1-5AMP28VDCTDC58 Circuit Breaker
SM3-1.5-28-VDC-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-845-6612?
The FSCG of the NSN 5925-00-845-6612 is 5925
Does the NSN 5925-00-845-6612 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-845-6612 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-845-6612 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-845-6612 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-845-6612 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

PL218858
1260-00-379-5366
Indicator
PL2199362-9
5995-01-260-9238
Electrical Power Cable Assembly
PL22-03
5950-01-371-0786
Power Transformer
PL22-3
5305-00-465-5536
Shoulder Screw
PL220-003
5935-01-540-1764
Electrical Receptacle Connector
PL220-004
5935-01-591-8778
Electrical Plug Connector
PL220-008
5935-01-274-8632
Electrical Receptacle Connector
PL220-011
5935-01-591-0450
Electrical Plug Connector
PL220-013
5935-01-271-9985
Electrical Receptacle Connector
PL220-013 W/RB
5935-00-821-6375
Electrical Plug Connector
PL220-016
5935-00-209-5645
Electrical Plug Connector
PL220-12
5935-01-270-0104
Electrical Plug Connector
PL2200-C1-S
6625-01-661-1811
Special Scale Meter
PL2200-ENC120-C1-X
6625-01-677-3967
Electrical Meter Housing
PL2200-ENN120-C1-X
6625-01-677-3968
Special Scale Meter