DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-229-1893 to receive an up to date pricing and availability quote by email.

5925-00-229-1893
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-229-1893
Item Name Code
00136
Assigment Date
02/14/1969 (57 years ago)

single pole type body style, 1.812 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.172 inches nominal overall length, 0.781 inches nominal center to center distance between terminals parallel to length, 0.703 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
2.172 inches nominal
Body Width
0.703 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.781 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.344 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
12.5 amperes ac and 12.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
110.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 ac and 575.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
Reset Method
automatic
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 50.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and moisture resistant and weatherproof
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10018895-012 Circuit Breaker
PSA-121/2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-229-1893?
The FSCG of the NSN 5925-00-229-1893 is 5925
Does the NSN 5925-00-229-1893 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-229-1893 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-229-1893 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-229-1893 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-229-1893 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Fri, Feb 14, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

2510-00
6530-01-225-2691
Wrist Restraint
2510.000
4320-00-567-4882
Centrifugal Pump Impeller
2510-000-99
6620-00-965-8075
Dial Indicating Pressure Gage
2510-0001
5930-01-293-3845
Pressure Switch
2510-00027IP
6620-00-856-2353
Dial Indicating Pressure Gage
2510-00028
6620-01-037-9601
Dial Indicating Pressure Gage
2510-00029
6620-01-097-7078
Dial Indicating Pressure Gage
2510-0007
5930-01-284-0393
Pressure Switch
2510-00076
6620-00-514-3829
Dial Indicating Pressure Gage
2510-0010
3439-00-175-3610
Electric Soldering Pencil
2510-00115
6620-00-527-9280
Dial Indicating Pressure Gage
2510-0015
6515-01-529-2208
Current Tester Switch
2510-0021
3439-00-497-2878
Electric Soldering Iron Tip
2510-0028
6680-01-625-4375
Liquid Level Switch
2510-0032
6680-01-625-4380
Liquid Level Switch