1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-196-3729

5925-00-196-3729

Find complete technical information, availability, and procurement data for: 5925-00-196-3729

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-196-3729 to receive an up to date pricing and availability quote by email.

5925-00-196-3729
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-196-3729
Item Name Code
00136
Assigment Date
06/12/1970 (56 years ago)

1.810 inches nominal distance between centerlines of mounting facilities parallel to body length, single pole type body style, 2.300 inches maximum body length, 0.750 inches nominal body width, 1.680 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.300 inches maximum
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.680 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.810 inches nominal
Switch Contact Arrangement
single pole, double throw
Boss Height
0.125 inches nominal
Mounting Surface To Terminal End Distance
2.500 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
60.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
36.000 nominal single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 control
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.187 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 15.000 maximum at 200 pct single location
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac
Switch Voltage Rating And Type In Volts
125.0 ac
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4MC17-6-25 Circuit Breaker
4MC3-6-25 Circuit Breaker
60931-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-196-3729?
The FSCG of the NSN 5925-00-196-3729 is 5925
Does the NSN 5925-00-196-3729 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-196-3729 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-196-3729 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-196-3729 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-196-3729 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Fri, Jun 12, 1970

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

13229E4281-3
5935-01-144-6595
Electrical Plug Connector Body
13229E4286
6145-01-476-2776
Electrical Power Cable
13229E4287
5961-01-475-7688
Diode Semiconductor Device
13229E4358
4140-01-440-7682
Centrifugal Fan Impeller
13229E5328
4610-01-304-6181
F Water Purification Filter Unit
13229E5334
4730-01-475-9640
Tube Coupling Assembly
13229E5336
4730-01-475-9298
Tube Tee
13229E5336-11
4730-01-475-9298
Tube Tee
13229E5341
5310-01-476-2038
Shouldered Washer
13229E5622
3815-01-315-1479
Pile Driver Catwalk
13229E5623
3815-01-362-1784
Pile Driver Catwalk
13229E5624
3815-01-362-5693
Pile Driver Catwalk
13229E5628
4710-01-384-8881
Metallic Bent Tube
13229E5629
4710-01-384-0757
Metallic Bent Tube
13229E5630-1
4320-01-336-3330
Axial Pistons Pump