1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-071-9844

5925-00-071-9844

Find complete technical information, availability, and procurement data for: 5925-00-071-9844

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-071-9844 to receive an up to date pricing and availability quote by email.

5925-00-071-9844
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-071-9844
Item Name Code
00136
Assigment Date
07/25/1967 (58 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

0.740 inches minimum and 0.760 inches maximum center to center distance between terminals parallel to width, 2.490 inches minimum and 2.510 inches maximum body length, multipole-multiple actuator type body style, 2.960 inches minimum and 3.040 inches maximum body width, 1.928 inches minimum and 1.948 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.490 inches minimum and 2.510 inches maximum
Body Width
2.960 inches minimum and 3.040 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.130 inches minimum and 0.150 inches maximum
Mounting Surface To Terminal End Distance
2.539 inches minimum and 2.683 inches maximum
Pole Quantity
4
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
8 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac fourth location
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac fourth location
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac third location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
Circuit Protection Type
overcurrent fourth location
Circuit Protection Type
overcurrent second location
Circuit Protection Type
overcurrent third location
Trip Release Method
magnetic-hydraulic second location
Trip Release Method
magnetic-hydraulic third location
Trip Release Method
magnetic-hydraulic fourth location
Trip Release Characteristic
time delay fourth location
Trip Release Characteristic
time delay second location
Trip Release Characteristic
time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 fourth location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 second location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 third location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, three, and four linked
Internal Trip Release Configuration
relay trip fourth location
Internal Trip Release Configuration
relay trip second location
Internal Trip Release Configuration
relay trip third location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
4.100 minimum at 200 pct and 14.000 maximum at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
4.100 minimum at 200 pct and 14.000 maximum at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current
4.100 minimum at 200 pct and 14.000 maximum at 200 pct fourth location
Inclosure Protection Type For Which Designed
fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant
Unpackaged Unit Weight
13.000 ounces nominal
Special Features
pole one is switch only
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
8 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM0666MG6-25-208VAC60C4 Circuit Breaker
AM0666MG6SW50-250VRC25-208V60C4 Circuit Breaker
CB5461R Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-071-9844?
The FSCG of the NSN 5925-00-071-9844 is 5925
Does the NSN 5925-00-071-9844 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-071-9844 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-071-9844 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-071-9844 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-071-9844 was assigned to the Federal Catalog?
It was assigned 58 years ago, on Tue, Jul 25, 1967

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M81714/11-22D
5940-01-243-6749
Quick Disconnect Splice Set
M81714/11-B12
5940-01-095-9952
Conductor Splice
M81714/11-C20
5940-01-134-8010
Conductor Splice
M81714/12
5940-01-134-5089
Conductor Splice
M81714/12-16A-1
5940-01-296-3341
Conductor Splice
M81714/12-16D-1
5940-01-507-0374
Sectiona Terminal Junction Block
M81714/12-16D-2
5940-01-508-1555
Sectiona Terminal Junction Block
M81714/12-20A-2
5940-01-038-2285
Conductor Splice
M81714/12-20B-1
5940-01-088-0270
Conductor Splice
M81714/12-20B-2
5940-01-134-5089
Conductor Splice
M81714/12-20D-1
5940-01-243-9865
Quick Disconnect Splice Set
M81714/12-20D-2
5940-01-243-9866
Quick Disconnect Splice Set
M81714/12-22D-1
5940-01-548-8571
Sectiona Terminal Junction Block
M81714/12-22D-2
5940-01-520-8055
Sectiona Terminal Junction Block
M81714/12016D-1
5940-01-296-3341
Conductor Splice