DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5985-01-334-6741 to receive an up to date pricing and availability quote by email.
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
twistable single tubing segment tubing twist type, 2b second flange all connection facilities thread class, internal, rectangular external, rectangular cross-sectional shape style, corrugated single tubing segment tubing wall construction style, right-hand second flange all connection facilities thread direction
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Cross-Sectional Shape Style
- internal, rectangular external, rectangular
- Thread Class
- 2b second flange all connection facilities
- Thread Direction
- right-hand second flange all connection facilities
- Tubing Wall Construction Style
- corrugated single tubing segment
- Tubing Twist Type
- twistable single tubing segment
- Tubing Twist Angle In Deg
- 90.0 single tubing segment
- Flange Quantity
- 2
- Flange Inside Width
- 1.118 inches minimum and 1.126 inches maximum second flange
- Flange Inside Width
- 1.250 inches minimum and 1.256 inches maximum first flange
- Flange Inside Height
- 0.493 inches minimum and 0.501 inches maximum second flange
- Flange Inside Height
- 0.617 inches minimum and 0.623 inches maximum first flange
- Flange Outside Width
- 1.860 inches minimum and 1.890 inches maximum first flange
- Flange Outside Width
- 1.860 inches minimum and 1.890 inches maximum second flange
- Flange Outside Height
- 1.860 inches minimum and 1.890 inches maximum first flange
- Flange Outside Height
- 1.860 inches minimum and 1.890 inches maximum second flange
- Flange Depth
- 0.415 inches minimum and 0.445 inches maximum first flange
- Flange Depth
- 0.610 inches minimum and 0.640 inches maximum second flange
- Flange Connecting Hole Diameter
- 0.164 inches minimum and 0.174 inches maximum first flange all connection facilities
- Voltage Standing Wave Ratio
- 1.12
- Insertion Loss In Decibels
- 0.10
- Maximum Operating Pressure
- 25.0 pounds per square inch gage
- Waveguide Outside Width
- 1.246 inches minimum and 1.254 inches maximum
- Nominal Thread Size
- 0.164 inches second flange all connection facilities
- Waveguide Inside Width
- 1.118 inches minimum and 1.126 inches maximum
- Waveguide Inside Height
- 0.493 inches minimum and 0.501 inches maximum
- Waveguide Outside Height
- 0.621 inches minimum and 0.629 inches maximum
- Waveguide Longer Offset Distance
- 7.440 inches nominal
- Flange Connecting Facility And Quantity
- 4 threaded hole second flange all connection facilities
- Flange Connecting Facility And Quantity
- 4 unthreaded hole first flange all connection facilities
- Flange Style
- choke type second flange
- Flange Style
- cover type first flange
- Waveguide Offset Distance
- 1.560 inches nominal
- Flexibility
- flexible single tubing segment
- Material
- aluminum alloy all tubing segment and flange
- Surface Treatment
- paint all tubing segment and flange outside surfaces
- Style Designator
- bend type
- Supplementary Features
- frequency 8.49 to 9.61 ghz
- Thread Series Designator
- unc second flange all connection facilities
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 8811-3120-1 | Waveguide Assembly |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5985-01-334-6741?
Does the NSN 5985-01-334-6741 have a Schedule B code assigned?
Does NSN 5985-01-334-6741 require demilitarization?
Does NSN 5985-01-334-6741 contain precious materials?
Does NSN 5985-01-334-6741 contain hazardous materials?
When the NSN 5985-01-334-6741 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: