NSN 6515-01-453-4003

Defibrillator/monitor-recorder S

FSC: 6515     NIIN: 014534003

DODParts.com distributes supplies equipment medical and surgical instruments, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6515-01-453-4003 to receive an up to date pricing and availability quote by email.

Product Characteristics

NSN:
6515014534003
Demilitarization:
NO
INC:
47731
Shelf Life:
N/A
Furnished Items:
Ecg cable, 1 ea; defiib paddlles, 2 ea (1 pediatric and 1 adult); monitoring electrodes, 24 sets; pacing electrodes, 10 sets; nicad battery, 4 ea; recorder paper, 6 rolls; applicable power cables, and operator/service manual, 2 ea; conductive pads, 3 sets
Part Name Assigned By Controlling Agency:
Defibrillator monitor recorder: 120/230v 50/60hz ac or dc
Special Features:
With pacing; portable; both line and battery powered; auxillary power supply 110 vac, 50 hz; battery charger supply 110/220 vac, 50/60 hz; dual voltage rated; c/o: non-invasive pacemaker, defibrillator, ecg monitor, recorder, and external batterty charger; unit is impact resistant and operable in wet environments; the recorder shall annotate at a : time, date, heart rate, pacer parameters, defibrillator parameters, gain and lead; shall have six adjustable discrete energy steps including, but not limited to, 10, 50, 100, 200, 300 and 360 joules; external pacemaker shall have non-invasive cardiac pacing rates from 40 through 150 beats/minute; uses disposable, pre-gelled electrodes; demand pacemaker capable of asynchronous operation; delivered output current is continuously adjustble over the range of 0-140 milliamps
Supplementary Features:
Note: reusable padded storage case was waived for the purchase. Aeromedically certified for fixed wing, wide body aircraft only.

Part Numbers

  • 00-0454
    DEFENSE LOGISTICS AGENCY
  • 804200-59
    PHYSIO-CONTROL, INC.
  • LIFEPAK 10-59
    PHYSIO-CONTROL, INC.
  • SP0200-98-D-8013
    PHYSIO-CONTROL, INC.

Shipping & Handling

HMIRS:

No MSDS. No hazardous material.

ESD:

No known electrostatic discharge.

Schedule B:

9018194000 - Electro-diagnostic apparatus for functional exploratory examination, and parts and accessories thereof.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 6515-01-453-4003 defibrillator/monitor-recorder s
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms