- Sitemap »
- Electrical And Electronic Equipment Components »
- Circuit Breakers »
- NSN 5925-01-435-7536
NSN 5925-01-435-7536
Circuit Breaker
FSC: 5925 NIIN: 014357536DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-435-7536 to receive an up to date pricing and availability quote by email.
Product Characteristics
NSN:
5925014357536
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Single pole type
Bushing Length:
0.500 inches
Body Length:
1.260 inches
Body Width:
0.550 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
0.690 inches
Mounting Surface To Terminal End Distance:
1.530 inches
Pole Quantity:
1
Mounting Facility Type And Quantity:
1 threaded bushing
Thready Qty Per Inch (tpi):
27
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes ac single location and 5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac single location and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
50.0 ac single location and 50.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 single location
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Internal Trip Release Configuration:
Series trip single location
Thread Size:
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
5.000 at 200 pct single location and 25.000 at 200 pct single location
Trip Release Ambient Tempurature Rating:
21.0 degrees celsius single location
Frequency In Hertz:
60.0 single location
Thread Series Designator:
Uns
Terminal Type And Quantity:
2 quick disconnect, male
Part Numbers
-
1658-G21-P10-5A
OAKLAND INDUSTRIES LTD
Shipping & Handling
HMIRS:No information in HMIRS. Hazardous material unknown.
ESD:No known electrostatic discharge.
Schedule B:8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.
Professional Distribution
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
Need current pricing? Get a quote
Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.
Cage Codes
Price Quote
NSN 5925-01-435-7536Enter the qty you are looking for and your basic contact information to receive price quote by email.