Product Characteristics

NSN:
5925013700889
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Rectangular dimensional envelope
Overall Length:
1.840 inches
Overall Height:
0.400 inches
Overall Width:
1.560 inches
Case Material:
Plastic
Pole Quantity:
1
Mounting Facility Type And Quantity:
2 clip
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac single location and 10.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
120.0 ac single location and 32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac single location and 2000.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Magnetic single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 single location
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Internal Trip Release Configuration:
Series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current:
2.750 at 200 pct single location and 30.000 at 200 pct single location
Frequency In Hertz:
50.0 single location or 60.0 single location
Terminal Type And Quantity:
2 tab, solder lug

Part Numbers

  • 0000-8067-03
    HILL ROSS CONTROLS CORP
  • R11-2-10.0A-806EV
    SENSATA TECHNOLOGIES MARYLAND, INC
  • R11-2-10.0A-B06EV
    SENSATA TECHNOLOGIES MARYLAND, INC

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-01-370-0889 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms
McAfee Secure