NSN 5925-01-365-9941

Circuit Breaker

FSC: 5925     NIIN: 013659941

DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-365-9941 to receive an up to date pricing and availability quote by email.

Product Characteristics

NSN:
5925013659941
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Multipole-multiple actuator type
Body Length:
2.500 inches
Body Width:
3.000 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
1.938 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.062 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Boss Height:
0.140 inches
Mounting Surface To Terminal End Distance:
2.611 inches
Pole Quantity:
4
Mounting Facility Type And Quantity:
8 threaded hole
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent first locationovercurrent second locationovercurrent third locationundervoltage fourth location
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay first locationtime delay second locationtime delay third locationinstantaneous fourth location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Internal Trip Release Configuration:
Series trip first locationseries trip second locationseries trip third locationrelay trip fourth location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct first location and 20.000 at 200 pct first location2.000 at 200 pct second location and 20.000 at 200 pct second location2.000 at 200 pct third location and 20.000 at 200 pct third location
Frequency In Hertz:
400.0 first location400.0 second location400.0 third location60.0 fourth location
Thread Series Designator:
Unc
Terminal Type And Quantity:
10 threaded stud

Demand History (Solicitations)

Solicitation Qty End Date Purchase Request Small Business
SPE7M519T051N 1 02/07/2019 0077890136 0%

Part Numbers

  • 10M10-1111
    BOEING COMPANY, THE
  • AM4-C3C3C3A18-A-10-2P4-107VRDC
    EATON CORP
  • UPL9111-23722-1
    SENSATA TECHNOLOGIES MARYLAND, INC

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-01-365-9941 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms