Product Characteristics

NSN:
5925013448929
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Rectangular dimensional envelope
Overall Length:
2.000 inches
Overall Height:
1.540 inches
Overall Width:
1.770 inches
Case Material:
Plastic
Fragility Factor:
Moderately rugged
Pole Quantity:
2
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
2 clip
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
32.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
Between pole one and two
Internal Trip Release Configuration:
Series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current:
4.500 at 200 pct all locations and 9.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Dustproof and fungus proof
Terminal Type And Quantity:
4 tab, solder lug

Part Numbers

  • 203-2-1-52F-203-4-1-
    BURGIN LUMBER CO INC
  • 203-2-1-52F-203-4-1-3
    SENSATA TECHNOLOGIES MARYLAND, INC

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-01-344-8929 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms
McAfee Secure