NSN 5925-01-262-2893

Circuit Breaker

FSC: 5925     NIIN: 012622893

DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-262-2893 to receive an up to date pricing and availability quote by email.

Product Characteristics

NSN:
5925012622893
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Length:
Between 2.468 inches and 2.532 inches
Body Width:
Between 2.968 inches and 3.032 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 1.906 inches and 1.970 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.722 inches and 0.782 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.030 inches and 2.094 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.722 inches and 0.782 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.108 inches and 0.172 inches
Mounting Surface To Terminal End Distance:
Between 2.688 inches and 2.752 inches
Pole Quantity:
4
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Fragile
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.150 at 200 pct third location and 1.500 at 200 pct third location
Inclosure Protection Type For Which Designed:
Fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant
Frequency In Hertz:
60.0 all locations
Unpackaged Unit Weight:
12.500 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
8 threaded stud

Demand History (Solicitations)

Solicitation Qty End Date Purchase Request Small Business
SPE7M521T462U 4 09/13/2021 0090993550 0%

Part Numbers

  • 47A521719P19
    LOCKHEED MARTIN CORPORATION
  • AM1-200-1
    EATON CORP
  • AM4-A3A3A3A6-20-3-RELAY 12VAC-P
    EATON CORP
  • AM4-A3A3A3A6-PL 1,2,3,20A-3PL41-
    EATON CORP
  • AM4-Z200-1
    EATON CORP

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-01-262-2893 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms
McAfee Secure