NSN 5925-01-256-9562

Circuit Breaker

FSC: 5925     NIIN: 012569562

DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-256-9562 to receive an up to date pricing and availability quote by email.

Product Characteristics

NSN:
5925012569562
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Rectangular dimensional envelope
Overall Length:
4.260 inches
Overall Height:
1.200 inches
Overall Width:
3.250 inches
Case Material:
Plastic
Unthreaded Mounting Hole Diameter:
0.172 inches
Fragility Factor:
Moderately rugged
Pole Quantity:
1
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
2 unthreaded hole
Storage Type:
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole:
35.0 amperes ac single location and 35.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac single location and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3600.0 ac single location and 3600.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 single location
Reset Method:
Automatic
Internal Trip Release Configuration:
Series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current:
16.000 at 200 pct single location and 55.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Dustproof
Trip Release Ambient Tempurature Rating:
40.0 degrees celsius single location
Frequency In Hertz:
400.0 single location
Test Data Document:
81349-mil-c-83383 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
2 threaded stud
Specification Data:
81349-mil-c-83383/1 government specification

Demand History (Solicitations)

Solicitation Qty End Date Purchase Request Small Business
SPE7M518T09R1 20 10/01/2018 0076394177 0%
SPE7M518T149Y 10 03/05/2018 0073099198 0%
SPE7M517TX692 10 10/10/2017 0071047106 0%

Part Numbers

  • 6510-001-35
    SAFRAN ELECTRICAL & POWER USA, LLC
  • M83383/01-07
    MILITARY SPECIFICATIONS
  • MIL-C-83383/1
    MILITARY SPECIFICATIONS
  • MIL-PRF-83383/1
    MILITARY SPECIFICATIONS

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-01-256-9562 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms