Product Characteristics

NSN:
5925012064328
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Multipole-multiple actuator type
Body Length:
Between 1.985 inches and 2.015 inches
Body Width:
Between 1.468 inches and 1.532 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 1.555 inches and 1.565 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.745 inches and 0.755 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.655 inches and 1.665 inches
Switch Contact Arrangement:
Double pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.745 inches and 0.755 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.125 inches and 0.135 inches
Mounting Surface To Terminal End Distance:
Between 1.898 inches and 1.962 inches
Pole Quantity:
2
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
25.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Auxiliary Switch Function And Quantity:
2 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at each pole
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct all locations and 20.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Dustproof and fungus proof
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts:
120.0 ac and 50.0 dc
Frequency In Hertz:
60.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
4 tab, solder lug

Part Numbers

  • JA2-A14-A-25-2
    EATON CORP
  • JA2-A14-A3-A-25-2
    EATON CORP
  • UPGH-11-1REC2-62F-253-90
    SENSATA TECHNOLOGIES MARYLAND, INC

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-01-206-4328 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms