DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other
components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-051-5288 to receive an up to date pricing and availability quote by email.
Product Characteristics
Body Style:
Multipole-multiple actuator type
Mounting Slot Width:
0.164 inches
Body Length:
5.800 inches
Body Height:
2.609 inches
Center To Center Distance Between Terminals Parallel To Length:
3.547 inches
Center To Center Distance Between Terminals Parallel To Width:
1.026 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
4.781 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.026 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.218 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole and 6 slot
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
2.0 amperes ac first location2.0 amperes ac second location10.0 amperes dc third location
Operating Voltage Type And Rating Per Pole In Volts:
480.0 ac first location480.0 ac second location28.0 dc third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac first location5000.0 ac second location5000.0 dc third location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.150 at 200 pct all locations and 0.600 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Frequency In Hertz:
50.0 first location or 60.0 first location50.0 second location or 60.0 second location
Unpackaged Unit Weight:
2.000 pounds
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Part Numbers
-
3192043
NAVAIR AND NAVSEA MANAGED
-
CF3-G3G3H3
EATON CORP
-
CF3-Z224-2W
HEINEMANN ELECTRIC CANADA INC
Stock Availability
Stock quantities are grouped by condition code below.
Notice: Availability of this item was updated on 06-27-2024 and may not reflect the most current stock quantity. Request a quote for up to date pricing and availability.
Shipping & Handling
HMIRS:
No information in HMIRS. Hazardous material unknown.
ESD:
No known electrostatic discharge.
Schedule B:
8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.
Professional Distribution
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections