- Sitemap »
- Electrical And Electronic Equipment Components »
- Circuit Breakers »
- NSN 5925-00-840-9071
NSN 5925-00-840-9071
Circuit Breaker
FSC: 5925 NIIN: 008409071DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-840-9071 to receive an up to date pricing and availability quote by email.
Product Characteristics
NSN:
5925008409071
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Single pole type
Bushing Length:
0.250 inches
Body Length:
2.189 inches
Body Width:
0.750 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
1.188 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.812 inches
Mounting Surface To Terminal End Distance:
2.000 inches
Pole Quantity:
1
Mounting Facility Type And Quantity:
2 threaded hole
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
50.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3000.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
138.0 single location
Ultimate Trip Time Per Pole In Seconds:
3600.000 single location
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Nontrip free
Manual Actuator Type And Quantity:
1 push-pull
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Internal Trip Release Configuration:
Series trip single location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
10.000 at 200 pct single location and 50.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Explosion proof and corrosion resistant
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius single location
Test Data Document:
81349-mil-c-7079 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Unc
Terminal Type And Quantity:
2 screw
Specification Data:
96906-ms24506 government standard
Part Numbers
-
AN3160-50
AERONAUTICAL STANDARDS GROUP -
MIL-C-7079
MILITARY SPECIFICATIONS -
MS24506-50
MILITARY STANDARDS
Shipping & Handling
HMIRS:No information in HMIRS. Hazardous material unknown.
ESD:No known electrostatic discharge.
Schedule B:8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.
Professional Distribution
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
Need current pricing? Get a quote
Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.
Price Quote
NSN 5925-00-840-9071Enter the qty you are looking for and your basic contact information to receive price quote by email.