FSC: 5925 NIIN: 008373663DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-837-3663 to receive an up to date pricing and availability quote by email.
Product Characteristics
NSN:
5925008373663
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Multipole-multiple actuator type
Body Length:
3.719 inches
Body Width:
3.052 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
3.063 inches
Center To Center Distance Between Terminals Parallel To Width:
1.031 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.031 inches
Boss Height:
0.156 inches
Mounting Surface To Terminal End Distance:
3.359 inches
Pole Quantity:
3
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
65.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
120.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Ultimate Trip Time Per Pole In Seconds:
0.800 all locations and 3.000 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.300 at 200 pct all locations and 1.000 at 200 pct all locations and 0.100 at 300 pct all locations and 0.300 at 300 pct all locations and 0.040 at 400 pct all locations and 0.150 at 400 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant and explosion resistant
Frequency In Hertz:
400.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Part Numbers
-
3XAM1516MG3-65AMP120VACTDC13
EATON CORP -
3XAM1516MG3-65AMP120VACTDC3-400
EATON CORP -
9157025
U S ARMY AVIATION AND MISSILE
Shipping & Handling
HMIRS:No information in HMIRS. Hazardous material unknown.
ESD:No known electrostatic discharge.
Schedule B:8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.
Professional Distribution
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections

Need current pricing? Get a quote
Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Price Quote
NSN 5925-00-837-3663Enter the qty you are looking for and your basic contact information to receive price quote by email.