Product Characteristics

NSN:
5925007587955
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Bushing Length:
Between 0.146 inches and 0.166 inches
Body Length:
Between 2.490 inches and 2.510 inches
Body Width:
Between 1.510 inches and 1.530 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 1.180 inches and 1.200 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.802 inches and 1.822 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.740 inches and 0.760 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
Between 1.990 inches and 2.010 inches
Pole Quantity:
2
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
32.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.130 at 200 pct all locations and 0.450 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Dustproof and fungus proof
Thread Series Designator:
Unc
Terminal Type And Quantity:
4 tab w/screw

Part Numbers

  • 1179004P2
    BAE SYSTEMS INFORMATION AND
  • 2XAM17-10-32VDC56
    EATON CORP
  • DMS 83059B
    DLA LAND AND MARITIME

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections