NSN 5925-00-752-6903

Circuit Breaker

FSC: 5925     NIIN: 007526903

DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-752-6903 to receive an up to date pricing and availability quote by email.

Product Characteristics

NSN:
5925007526903
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Single pole type
Body Length:
1.891 inches
Body Width:
1.188 inches
Body Height:
1.407 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
0.844 inches
Unthreaded Mounting Hole Diameter:
0.174 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.574 inches
Pole Quantity:
1
Mounting Facility Type And Quantity:
2 unthreaded hole
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
600.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
130.0 single location
Reset Method:
Automatic
Internal Trip Release Configuration:
Series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current:
50.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Corrosion resistant and dustproof and fungus resistant
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius single location
Terminal Type And Quantity:
2 quick disconnect, female

Part Numbers

  • 7526903
    U S ARMY TANK AUTOMOTIVE COMMAND
  • C9115-2-30
    SENSATA TECHNOLOGIES, INC
  • MILC13516TYPE2GRADEACLASS1
    MILITARY SPECIFICATIONS

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-00-752-6903 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms