NSN 5925-00-619-3652

Circuit Breaker

FSC: 5925     NIIN: 006193652

DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-619-3652 to receive an up to date pricing and availability quote by email.

Product Characteristics

NSN:
5925006193652
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Single pole type
Overall Length:
50.8 millimeters
Body Width:
19.81 millimeters
Case Material:
Metal
Center To Center Distance Between Terminals Parallel To Length:
Between 17.14 millimeters and 17.27 millimeters
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
39.62 millimeters
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
34.97 millimeters
Pole Quantity:
1
Mounting Facility Type And Quantity:
2 terminal
Storage Type:
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
12.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Instantaneous single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 single location
Reset Method:
Automatic
Internal Trip Release Configuration:
Series trip single location
Inclosure Protection Type For Which Designed:
Hermetically sealed
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius single location
Terminal Type And Quantity:
2 threaded stud

Part Numbers

  • 30055-30
    COLE HERSEE COMPANY
  • 30055-30STK
    COLE HERSEE COMPANY
  • 3-318-010006
    LANDOLL CORPORATION
  • 36821
    ALLIANZ SWEEPER COMPANY
  • 851091203
    BOMAG USA
  • CH30055-30
    COLE HERSEE COMPANY

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-00-619-3652 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms
McAfee Secure