NSN 5925-00-324-0142

Circuit Breaker

FSC: 5925     NIIN: 003240142

DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-324-0142 to receive an up to date pricing and availability quote by email.

NSN 5925-00-324-0142 Description

Single pole type body style, 0.332 inches bushing length, 1.562 inches body length, 0.625 inches body width, metal case material.

Product Characteristics

NSN:
5925003240142
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Single pole type
Bushing Length:
Between 0.332 inches and 0.380 inches
Body Length:
1.562 inches
Body Width:
0.625 inches
Case Material:
Metal
Center To Center Distance Between Terminals Parallel To Length:
Between 0.844 inches and 0.906 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.605 inches
Pole Quantity:
1
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac single location and 20.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac single location and 50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac single location and 1000.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Magnetic single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Internal Trip Release Configuration:
Relay trip single location
Thread Size:
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.070 at 200 pct single location and 0.700 at 200 pct single location
Inclosure Protection Type For Which Designed:
Corrosion resistant and hermetically sealed and humidity resistant and shockproof and vibrationproof and salt water resistant and fungus resistant
Frequency In Hertz:
60.0 single location
Unpackaged Unit Weight:
2.100 ounces
Precious Material And Location:
Contact surfaces silver
Precious Material:
Silver
Thread Series Designator:
Unef
Terminal Type And Quantity:
1 tab, solder lug and 2 wire hook

Part Numbers

  • 226719-000
    BAE SYSTEMS INFORMATION AND
  • AP4-5186-0
    SENSATA TECHNOLOGIES MARYLAND, INC
  • PSM6-20
    EATON CORP
  • PSM6-20-250AC50DCRT18DC50MALKTAB
    EATON CORP

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-00-324-0142 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms
McAfee Secure