NSN 5925-00-279-6762 Description
Single pole type body style, 5.240 inches body length, 1.490 inches body width, 2.678 inches body height, plastic case material.
Product Characteristics
Body Style:
Single pole type
Body Length:
Between 5.240 inches and 5.260 inches
Body Width:
Between 1.490 inches and 1.510 inches
Body Height:
Between 2.678 inches and 2.698 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 4.349 inches and 4.369 inches
Unthreaded Mounting Hole Diameter:
0.190 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 4.349 inches and 4.369 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.974 inches and 0.994 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.208 inches and 0.228 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole and 4 unthreaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
50.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
125.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 dc single location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 single location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Internal Trip Release Configuration:
Series trip single location
Thread Size:
0.164 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.400 at 200 pct single location and 1.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Dustproof and fungus proof
Thread Series Designator:
Unc
Terminal Type And Quantity:
4 compression
Part Numbers
-
1163SMG4-50-125DC2
EATON CORP
-
12-187
ESPEY MFG. & ELECTRONICS CORP.
-
SM-B-185207
US ARMY COMMUNICATIONS &
Shipping & Handling
HMIRS:
No information in HMIRS. Hazardous material unknown.
ESD:
No known electrostatic discharge.
Schedule B:
8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.
Professional Distribution
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections