NSN 5925-00-148-8124 Description
+0.1177/+0.1214 inches thread pitch diameters, multipole-multiple actuator type body style, 2.490 inches body length, 2.990 inches body width.
Product Characteristics
Thread Pitch Diameters:
+0.1177 to 0.1214 inches
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.490 inches and 2.510 inches
Body Width:
Between 2.990 inches and 3.010 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.928 inches and 1.948 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.052 inches and 2.072 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.740 inches and 0.760 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.130 inches and 0.150 inches
Mounting Surface To Terminal End Distance:
Between 2.461 inches and 2.481 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
60.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
2.200 at 200 pct third location and 20.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Fungus resistant and vibration resistant
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
10.0 ac
Switch Voltage Rating And Type In Volts:
125.0 ac
Frequency In Hertz:
50.0 all locations or 60.0 all locations or 400.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
10 threaded stud
Part Numbers
-
AM4-Z1-3
EATON CORP
-
APL5111-1REC2-3235-3
SENSATA TECHNOLOGIES MARYLAND, INC
-
SM-A-742924-3
US ARMY COMMUNICATIONS &