Multipole-multiple actuator type body style, 5.769 inches body length, 2.041 inches body width, plastic case material, 3.516 inches center to center distance between terminals parallel to length.

Product Characteristics

NSN:
5925001402357
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Body Style:
Multipole-multiple actuator type
Body Length:
Between 5.769 inches and 5.831 inches
Body Width:
Between 2.041 inches and 2.103 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 3.516 inches and 3.578 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.016 inches and 1.036 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.719 inches and 2.781 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.016 inches and 1.036 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.209 inches and 0.229 inches
Mounting Surface To Terminal End Distance:
Between 3.172 inches and 3.296 inches
Pole Quantity:
2
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
125.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Relay trip second location
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
30.000 at 200 pct first location and 100.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant and shock resistant and vibration resistant
Switch Terminal Type:
Tab, solder lug
Criticality Code Justification:
Feat
Switch Current Rating And Type In Amps:
5.0 ac
Switch Voltage Rating And Type In Volts:
125.0 ac
Special Features:
Communication center, patching necessary to weapons system
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud

Part Numbers

  • CD2-Z102-1
    EATON CORP
  • SMA-742929-1
    US ARMY COMMUNICATIONS &

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-00-140-2357 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms
McAfee Secure