NSN 5925-00-056-8926 Description
+0.3503/+0.3537 inches thread pitch diameters, multipole-single actuator type body style, 0.380 inches bushing length, 1.562 inches body length.
Product Characteristics
Thread Pitch Diameters:
+0.3503/+0.3537 inches
Body Style:
Multipole-single actuator type
Bushing Length:
0.380 inches
Body Length:
1.562 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 0.407 inches and 0.469 inches
Center To Center Distance Between Terminals Parallel To Width:
0.640 inches
Nonturn Device Location:
At 3 oclock and at 9 oclock
Nonturn Device Radius:
Between 0.610 inches and 0.640 inches
Nonturn Device Length:
0.130 inches
Nonturn Device Diameter:
Between 0.235 inches and 0.265 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.780 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
2.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
Between pole one and two
Internal Trip Release Configuration:
Shunt trip all locations
Thread Size:
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.700 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Vibrationproof and
Frequency In Hertz:
50.0 all locations or 60.0 all locations
Unpackaged Unit Weight:
3.600 ounces
Thread Series Designator:
Unef
Terminal Type And Quantity:
6 wire hook
Part Numbers
-
712A202
SENSATA TECHNOLOGIES MARYLAND, INC
-
AP-12-3-61-202
SENSATA TECHNOLOGIES MARYLAND, INC
Shipping & Handling
HMIRS:
No information in HMIRS. Hazardous material unknown.
ESD:
No known electrostatic discharge.
Schedule B:
8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.
Professional Distribution
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections