NSN 5925-00-056-0897

Circuit Breaker

FSC: 5925     NIIN: 000560897

DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-056-0897 to receive an up to date pricing and availability quote by email.

NSN 5925-00-056-0897 Description

+0.3503/+0.3537 inches thread pitch diameters, multipole-single actuator type body style, 0.380 inches bushing length, 1.562 inches body length.

Product Characteristics

NSN:
5925000560897
Demilitarization:
NO
INC:
00136
Shelf Life:
N/A
Thread Pitch Diameters:
+0.3503/+0.3537 inches
Body Style:
Multipole-single actuator type
Bushing Length:
0.380 inches
Body Length:
1.562 inches
Body Width:
1.937 inches
Case Material:
Metal
Center To Center Distance Between Terminals Parallel To Length:
Between 0.860 inches and 0.890 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.610 inches and 0.640 inches
Nonturn Device Location:
At 3 oclock and at 9 oclock
Nonturn Device Radius:
0.625 inches
Nonturn Device Length:
0.130 inches
Nonturn Device Diameter:
0.140 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.780 inches
Pole Quantity:
3
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
300.0 milliamperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Relay trip all locations
Thread Size:
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.850 at 200 pct all locations and 4.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Hermetically sealed and shock resistant and vibration resistant
Unpackaged Unit Weight:
5.400 ounces
Thread Series Designator:
Unef
Terminal Type And Quantity:
6 wire hook and 6 tab, solder lug

Part Numbers

  • 1555169-2
    NAVAIR AND NAVSEA MANAGED
  • 603B301
    SENSATA TECHNOLOGIES MARYLAND, INC
  • AP-112-4-52-301
    SENSATA TECHNOLOGIES MARYLAND, INC

Shipping & Handling

HMIRS:

No information in HMIRS. Hazardous material unknown.

ESD:

No known electrostatic discharge.

Schedule B:

8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.

Professional Distribution

  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   AS9120 Quality Standards
  •   100% Quality Inspections
ITAR registered supplier

Need current pricing? Get a quote

Receive an official quote via email with pricing, availability, condition, and certifications when you submit this form below.

Qty:
Email Address:

NSN: 5925-00-056-0897 circuit breaker
Your Name:
Phone Number:
Company:
Privacy Policy    Order Terms
McAfee Secure