NSN 5925-00-055-6046 Description
Multipole-single actuator type body style, 9.313 inches body length, 4.063 inches body width, 3.751 inches body height, plastic case material.
Product Characteristics
Body Style:
Multipole-single actuator type
Body Length:
Between 9.313 inches and 9.437 inches
Body Width:
Between 4.063 inches and 4.187 inches
Body Height:
Between 3.751 inches and 3.875 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 3.782 inches and 3.906 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.313 inches and 1.437 inches
Unthreaded Mounting Hole Diameter:
0.281 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 7.063 inches and 7.187 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.313 inches and 1.437 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.438 inches and 0.562 inches
Arc Quenching Method:
Deion
Mounting Facility Type And Quantity:
4 unthreaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Maximum Continuous Load Current Rating Per Pole:
100.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
208.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
15000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal-magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Trip Delay Time In Seconds Per Rated Continuous Current:
50.000 at 200 pct all locations and 210.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
General purpose
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius all locations
Frequency In Hertz:
60.0 all locations
Terminal Type And Quantity:
6 compression
Part Numbers
-
F3060
EATON CORPORATION
-
J74-0028
WARD LEONARD CT LLC
Shipping & Handling
HMIRS:
No information in HMIRS. Hazardous material unknown.
ESD:
No known electrostatic discharge.
Schedule B:
8536200040 - Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi.
Professional Distribution
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections