DODParts.com distributes circuit breakers, aircraft parts and consumables, electrical parts, fittings and other
components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-009-6341 to receive an up to date pricing and availability quote by email.
NSN 5925-00-009-6341 Description
Multipole-multiple actuator type body style, 1.985 inches body length, 2.245 inches body width, plastic case material, 1.555 inches center to center distance between terminals parallel to length.
Product Characteristics
Body Style:
Multipole-multiple actuator type
Body Length:
Between 1.985 inches and 2.015 inches
Body Width:
Between 2.245 inches and 2.255 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.555 inches and 1.565 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.745 inches and 0.755 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.655 inches and 1.665 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.745 inches and 0.755 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.125 inches and 0.135 inches
Mounting Surface To Terminal End Distance:
Between 1.835 inches and 1.845 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct all locations and 20.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Dustproof and fungus resistant
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
10.0 ac and 3.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 50.0 dc
Frequency In Hertz:
60.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 tab, solder lug
Part Numbers
-
D5-19-4813-2
EDGEWOOD CHEMICAL BIOLOGICAL CENTER
-
JA3-A2A3A3-10-2
EATON CORP
-
JA3S-A2A3A3-EB-01-D-05-10-2
EATON CORP