1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-01-348-4281

5930-01-348-4281

Find complete technical information, availability, and procurement data for: 5930-01-348-4281

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-01-348-4281 to receive an up to date pricing and availability quote by email.

5930-01-348-4281
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-348-4281
Item Name Code
02134
Assigment Date
11/09/1991 (34 years ago)

A switch which is externally actuated by a lever and whose contacts open and close with an instantaneous (snap) action; includes items having one or more momentary positions. Includes switches (snap action) which use mercury to bridge contacts, and assemblages of complete switches (snap action) having common actuators. Excludes:switch,lever; switch,rotary; switch,knife; switch,sensitive; and switch,box.

2a single mounting facility thread class, 2.165 inches nominal overall length, 0.219 inches nominal 1st actuator0.086 inches nominal 2nd actuator flat height, 0.292 inches minimum and 0.332 inches maximum single mounting facility thread length, 0.230 inches minimum and 0.270 inches maximum all actuators first flat length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
2a single mounting facility
Thread Length
0.292 inches minimum and 0.332 inches maximum single mounting facility
Overall Length
2.165 inches nominal
First Flat Length
0.230 inches minimum and 0.270 inches maximum all actuators
Flat Height
0.219 inches nominal 1st actuator0.086 inches nominal 2nd actuator
Shaft Diameter
0.248 inches minimum and 0.251 inches maximum 1st actuator0.123 inches minimum and 0.126 inches maximum 2nd actuator
Shaft Length
0.355 inches minimum and 0.395 inches maximum 1st actuator0.750 inches nominal 2nd actuator
Overall Diameter
0.672 inches minimum and 0.702 inches maximum
Individual Section Quantity
1
Nonturn Device Type
slotted bushing at 3:00 o'clock
Operating Temp Range
-65.0 to 85.0 celsius
Switch Contact Basic Design
nonpile-up nonsymmetrical
Mounting Method
threaded bushing single mounting facility
Nominal Thread Size
0.375 inches single mounting facility
Contact Voltage Rating In Volts
115.0 ac at sea level28.0 dc at sea level
Switch Actuator Indexing Position Quantity
6 1st actuator9 2nd actuator
Shaft Type
round, flatted w/through hole 1st actuatorround, flatted 2nd actuator
Terminal Type
printed circuit
Switch Actuator Positioning Increment
36.0 degrees all actuators
Detent Rotational Torque Range
+0.250 to 2.000 inch-pounds all actuators
Switch Actuator Stop Device Type
adjustable stop all actuators
Contact Load Current Rating
150.0 milliamperes resistive load ac at sea level30.0 milliamperes inductive load and 200.0 milliamperes resistive load dc at sea level
Precious Material And Location
contacts silver and terminal and contact surfaces gold
Style Designator
tap, circular, bushing mount
Thread Series Designator
unef single mounting facility

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
283-0011-040 Rotary Switch
71MY233332 Rotary Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-348-4281?
The FSCG of the NSN 5930-01-348-4281 is 5930
Does the NSN 5930-01-348-4281 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509020
Does NSN 5930-01-348-4281 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-348-4281 contain precious materials?
Item contains silver.
Does NSN 5930-01-348-4281 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-348-4281 was assigned to the Federal Catalog?
It was assigned 34 years ago, on Sat, Nov 9, 1991

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RBR57L60402BR
5905-01-256-9947
Wire Wound Fixed Resistor
RBR57L60402FR
5905-00-314-3477
Wire Wound Fixed Resistor
RBR57L61671BR
5905-01-274-3936
Wire Wound Fixed Resistor
RBR57L61R00BR
5905-01-263-4550
Wire Wound Fixed Resistor
RBR57L634R0BR
5905-00-197-4171
Wire Wound Fixed Resistor
RBR57L64902FR
5905-01-049-2087
Wire Wound Fixed Resistor
RBR57L64R00BP
5905-01-256-1179
Wire Wound Fixed Resistor
RBR57L64R00BR
5905-01-256-1179
Wire Wound Fixed Resistor
RBR57L65R00BR
5905-01-255-7179
Wire Wound Fixed Resistor
RBR57L66501BR
5905-00-317-8316
Wire Wound Fixed Resistor
RBR57L66670AR
5905-01-266-0086
Wire Wound Fixed Resistor
RBR57L67R00BR
5905-01-255-7180
Wire Wound Fixed Resistor
RBR57L68000BR
5905-00-307-3909
Wire Wound Fixed Resistor
RBR57L68002BR
5905-01-020-3194
Wire Wound Fixed Resistor
RBR57L68101BR
5905-00-007-7229
Wire Wound Fixed Resistor