1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-01-322-2625 /
  5. M24236/25-AGJBA

M24236/25-AGJBA

View detailed technical data, stock status, and sourcing information for: M24236/25-AGJBA

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part M24236/25-AGJBA to receive an up to date pricing and availability quote by email.

M24236/25-AGJBA
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-322-2625
Item Name Code
00451
Assigment Date
06/30/1990 (36 years ago)

A switch that is actuated by changes in ambient temperature. Excludes:circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).

0.394 inches minimum single threaded bushing thread length, 2.609 inches nominal overall length, 0.665 inches maximum body diameter, a2a single threaded bushing thread class, 1.106 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
a2a single threaded bushing
Thread Length
0.394 inches minimum single threaded bushing
Overall Length
2.609 inches nominal
Body Diameter
0.665 inches maximum
Body Length
1.106 inches nominal
Temp Sensing Element Type
internal sensor
Width Across Flats
0.990 inches minimum and 1.010 inches maximum
Operating Temp Rating
-10.0 fahrenheit minimum and 400.0 fahrenheit maximum
Mounting Method
threaded bushing
Features Provided
hermetically sealed case
Contact Action Stimulus
increase
Nominal Thread Size
0.750 inches single threaded bushing
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
Terminal Type
connector, receptacle
Contact Load Current Rating
2.0 amperes resistive load and 1.0 amperes inductive load and 1.0 amperes lamp load second voltage
Contact Load Current Rating
2.0 amperes resistive load and 1.5 amperes inductive load and 500.0 milliamperes lamp load first voltage
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
Contact Stimulus Rating
155.00 actuation point nominal degrees fahrenheit and 152.00 deactuation point minimum degrees fahrenheit and 150.00 deactuation point maximum degrees fahrenheit
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
Frequency In Hertz
60.0 first voltage
Media For Which Designed
gas
Style Designator
cylindrical w/flange
Test Data Document
"81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unf single threaded bushing
Specification/Standard Data
81349-mil-s-24236/25 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M24236/25-AGJBA Thermostatic Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-322-2625?
The FSCG of the NSN 5930-01-322-2625 is 5930
Does the NSN 5930-01-322-2625 have a Schedule B code assigned?
Yes, the Schedule B code is 9032100000
Does NSN 5930-01-322-2625 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-322-2625 contain precious materials?
Item does not contain precious metal.
Does NSN 5930-01-322-2625 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-322-2625 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Sat, Jun 30, 1990

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RWR80S1650FM
5905-01-187-1631
Resistor,fixed,wire Wound,induct
RWR80S1650FP
5905-01-187-1631
Resistor,fixed,wire Wound,induct
RWR80S1650FR
5905-01-187-1631
Resistor,fixed,wire Wound,induct
RWR80S1650FS
5905-01-187-1631
Resistor,fixed,wire Wound,induct
RWR80S1651FM
5905-01-590-1075
Resistor,fixed,wire Wound,induct
RWR80S1651FR
5905-00-481-1111
Resistor,fixed,wire Wound,induct
RWR80S1651FS
5905-01-049-2088
Resistor,fixed,wire Wound,induct
RWR80S1690BR
5905-01-195-3234
Resistor,fixed,wire Wound,induct
RWR80S1690BS
5905-01-195-3234
Resistor,fixed,wire Wound,induct
RWR80S1690DR
5905-01-261-3415
Resistor,fixed,wire Wound,induct
RWR80S1690DS
5905-01-261-3415
Resistor,fixed,wire Wound,induct
RWR80S1690FM
5905-01-174-2455
Resistor,fixed,wire Wound,induct
RWR80S1690FP
5905-01-174-2455
Resistor,fixed,wire Wound,induct
RWR80S1690FR
5905-01-174-2455
Resistor,fixed,wire Wound,induct
RWR80S1690FS
5905-01-174-2455
Resistor,fixed,wire Wound,induct