DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 20PS000EN120E050E to receive an up to date pricing and availability quote by email.

20PS000EN120E050E
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-311-3685
Item Name Code
00206
Assigment Date
11/24/1989 (36 years ago)

A switch that is actuated by changes in ambient temperature. Excludes:circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).

0.720 inches minimum and 0.840 inches maximum body length, dustproof hazardous locations/environmental protection, 0.820 inches minimum and 0.940 inches maximum overall diameter, 0.125 inches nominal single connection outside diameter, 1.940 inches minimum and 2.060 inches maximum overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Hazardous Locations/Environmental Protection
dustproof
Overall Length
1.940 inches minimum and 2.060 inches maximum
Outside Diameter
0.125 inches nominal single connection
Body Length
0.720 inches minimum and 0.840 inches maximum
Overall Diameter
0.820 inches minimum and 0.940 inches maximum
End Item Identification
3810-01-205-2716 crane,wheel mounted
Pressure Switch Type
gage
Operating Temp Rating
-20.0 fahrenheit minimum and 150.0 fahrenheit maximum
Mounting Method
input port
Contact Action Stimulus
increase
Proof Pressure
300.00 pounds per square inch
Nominal Thread Size
0.125 inches single pressure connection
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
Sensing Element Burst Pressure
3500.00 pounds per square inch gage
Terminal Type
quick disconnect, male
Contact Load Current Rating
2.0 amperes resistive load single voltage
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
Contact Stimulus Rating
120.00 actuation point nominal pounds per square inch and 50.00 deactuation point nominal pounds per square inch
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
Pressure Connector Type
swivel nut, flared, threaded external single connection
Media For Which Designed
liquid
Style Designator
cylindrical
Thread Series Designator
npt single pressure connection

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
20PS000EN120E050E Pressure Switch
7-872-000673 Pressure Switch
7-872-001326 Pressure Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-311-3685?
The FSCG of the NSN 5930-01-311-3685 is 5930
Does the NSN 5930-01-311-3685 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509065
Does NSN 5930-01-311-3685 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-311-3685 contain precious materials?
Item does not contain precious metal.
Does NSN 5930-01-311-3685 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-311-3685 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Fri, Nov 24, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

FOR76COY
8465-01-665-0773
Duffel Bag
FOR76MC
8465-01-664-7547
Duffel Bag
FORAMATRON D-10
6520-01-583-3210
Dental Apex Locator
FORANE
6505-01-117-9832
Isoflurane
FORANE 113
6850-00-681-5688
Solvent Cleaning Compound
FORAX-LS2
5895-01-652-9067
Communication System
FORAX-RM-2U-A2L
5975-01-694-5718
Electrical Equipme Mounting Base
FORAX-RM-2U-R6L
5975-01-694-5871
Electrical Equipme Mounting Base
FORAX-RM-3U-A4L
5975-01-696-7931
Electrical Equipme Mounting Base
FORAX-RM-AIM-HF150
5998-01-694-5866
Input-Output Interface Unit
FORAX-RM-AIM-SC20W
5998-01-721-4521
Input-Output Interface Unit
FORAX-RM-APS-HP-AC
6130-01-694-6572
Power Supply
FORAX-RM-HF150-AC1
5995-01-694-6070
E Special Purpose Cable Assembly
FORAX-RM-HF150-RC1
5995-01-694-6073
E Special Purpose Cable Assembly
FORAX-RM-NIM
5998-01-694-5867
Input-Output Interface Unit