1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-01-059-6536

5930-01-059-6536

Find complete technical information, availability, and procurement data for: 5930-01-059-6536

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-01-059-6536 to receive an up to date pricing and availability quote by email.

5930-01-059-6536
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-059-6536
Item Name Code
00206
Assigment Date
04/15/1978 (48 years ago)

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes:baroswitch; switch,pressure-thermostatic; and switch,sensitive.

moisture resistant and salt spray resistant and vibration resistant hazardous locations/environmental protection, 2.000 inches nominal overall length, 0.188 inches nominal all connections outside diameter, 1.000 inches nominal overall width, 0.380 inches nominal overall height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Hazardous Locations/Environmental Protection
moisture resistant and salt spray resistant and vibration resistant
Overall Length
2.000 inches nominal
Outside Diameter
0.188 inches nominal all connections
Overall Height
0.380 inches nominal
Overall Width
1.000 inches nominal
Body Length
1.000 inches nominal
Unthreaded Mounting Hole Diameter
0.125 inches nominal
Longest Horizontal Distance Between Mounting Centers
0.718 inches nominal
Longest Vertical Distance Between Mounting Centers
0.718 inches nominal
Pressure Switch Type
differential
Operating Temp Rating
-65.0 celsius minimum and 125.0 celsius maximum
Mounting Method
base and unthreaded hole
Contact Action Stimulus
increase
Proof Pressure
4.00 pounds per square inch gage
Mounting Facility Pattern
four position rectangular
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
Terminal Type
tab, solder lug
Contact Load Current Rating
10.0 milliamperes resistive load single voltage
Contact Adjustability
actuation point not adjustable
Contact Stimulus Rating
1.20 actuation point minimum inches of water and 2.35 actuation point maximum inches of water
Contact Voltage Rating In Volts
30.0 dc at sea level single voltage
Pressure Connector Type
barbed, unthreaded external all connections
Media For Which Designed
gas or liquid
Precious Material And Location
terminal surfaces gold
Precious Material
gold
Style Designator
rectangular

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
886C103P0002 Pressure Switch
886C103P2 Pressure Switch
PSF100A-6153 Pressure Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-059-6536?
The FSCG of the NSN 5930-01-059-6536 is 5930
Does the NSN 5930-01-059-6536 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509065
Does NSN 5930-01-059-6536 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-059-6536 contain precious materials?
Item contains gold.
Does NSN 5930-01-059-6536 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-059-6536 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Sat, Apr 15, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

572-011-9001
5340-01-007-4950
Plug Button
572-0123-005
6145-01-257-4463
Electrical Special Purpose Cable
572-0127-000
5945-00-085-1443
Electromagnetic Relay
572-0128-001
6145-00-606-8237
Radio Frequency Cable
572-0133-003
6145-01-253-6688
Electrical Power Cable
572-0133-012
6145-01-208-0870
Electrical Power Cable
572-0133-013
6145-01-236-7605
Electrical Power Cable
572-0133-015
6145-00-156-4308
Electrical Special Purpose Cable
572-0133-016
6145-01-219-7318
Electrical Special Purpose Cable
572-0133-017
6145-01-239-0194
Electrical Special Purpose Cable
572-0133-018
6145-01-208-1644
Electrical Power Cable
572-0133-021
6145-01-210-3230
Electrical Power Cable
572-0133-027
6145-01-238-8940
Electrical Special Purpose Cable
572-0133-028
6145-01-217-9228
Electrical Special Purpose Cable
572-0133-030
6145-01-224-2450
Electrical Special Purpose Cable