1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-01-041-6486

5930-01-041-6486

Find complete technical information, availability, and procurement data for: 5930-01-041-6486

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-01-041-6486 to receive an up to date pricing and availability quote by email.

5930-01-041-6486
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-041-6486
Item Name Code
02134
Assigment Date
05/28/1977 (49 years ago)

A switch actuated by a definite angular rotation of the switch shaft about its axis. It consists of a body,switch and a control,rotary switch. For items having rated actuation travel and pressure characteristics, see switch,sensitive. Excludes relay,rotary; switch,stepping; and switch,telephone (as modified).

0.250 inches nominal single actuator shaft diameter, 3.800 inches nominal overall length, 0.250 inches nominal single actuator first flat length, 0.187 inches nominal single actuator flat height, 2b single mounting facility thread class

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
2b single mounting facility
Overall Length
3.800 inches nominal
First Flat Length
0.250 inches nominal single actuator
Flat Height
0.187 inches nominal single actuator
Shaft Diameter
0.250 inches nominal single actuator
Shaft Length
0.700 inches nominal single actuator
Overall Diameter
2.380 inches nominal
Individual Section Quantity
3
Longest Horizontal Distance Between Mounting Centers
1.000 inches nominal single mounting facility
Longest Vertical Distance Between Mounting Centers
1.000 inches nominal single mounting facility
Switch Contact Basic Design
nonpile-up symmetrical
Pole Quantity
1 each section front
Throw Quantity
10 each section rear
Mounting Method
threaded hole single mounting facility
Nominal Thread Size
0.190 inches single mounting facility
Contact Voltage Rating In Volts
115.0 ac at sea level
Contact Voltage Rating In Volts
28.0 dc at sea level
Shaft Flat/Slot Angular Location
180.0 degrees from contact position 1 single actuator
Rotor Through Connection Quantity
1 each section
Mounting Facility Pattern
four position rectangular single mounting facility
Switch Actuator Indexing Position Quantity
10 single actuator
Shaft Type
round, flatted single actuator
Terminal Type
screw
Contact Switching Action
breaks before makes each section rear
Switch Actuator Positioning Increment
36.0 degrees single actuator
Contact Load Current Rating
6.0 amperes resistive load and 3.0 amperes inductive load dc at sea level
Contact Load Current Rating
6.0 amperes resistive load ac at sea level
Style Designator
tap, circular, bushing mount
Thread Series Designator
unf single mounting facility

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-041-6486?
The FSCG of the NSN 5930-01-041-6486 is 5930
Does the NSN 5930-01-041-6486 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509025
Does NSN 5930-01-041-6486 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-041-6486 contain precious materials?
Precious metal content is unknown
Does NSN 5930-01-041-6486 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-041-6486 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Sat, May 28, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

227-7728
6130-01-091-5741
Power Supply
227-7731
6130-01-094-3223
Power Supply
227-7732
6130-01-107-1315
Power Supply
227-7733
6130-01-131-4949
Power Supply
227-7737
6130-01-033-9923
Power Supply
227-7740
6130-01-091-5742
Power Supply
227-7741
6130-01-091-5743
Power Supply
227-7747
6130-01-093-1804
Power Supply
227-7751
6130-01-089-2879
Power Supply
227-7776
6130-01-037-0104
Power Supply
227-7783
6130-01-041-3539
Power Supply
227-7790
5895-01-103-2404
Overvoltage Module
227-7790A
5895-01-103-2404
Overvoltage Module
227-7824
5962-01-015-5152
Linear Microcircuit
227-7833
6130-01-052-0946
Power Supply