DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-00-989-4285 to receive an up to date pricing and availability quote by email.

5930-00-989-4285
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-989-4285
Item Name Code
00184
Assigment Date
01/01/1962 (64 years ago)

submersible hazardous locations/environmental protection, 4.059 inches maximum overall height, 1.797 inches minimum and 1.827 inches maximum center to center distance between mounting facilities parallel to length, 2.156 inches maximum overall length, hole mount body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
hole mount
Hazardous Locations/Environmental Protection
submersible
Overall Length
2.156 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
1.797 inches minimum and 1.827 inches maximum
Overall Height
4.059 inches maximum
Overall Width
1.531 inches maximum
Body Length
2.156 inches maximum
Body Width
1.531 inches maximum
Body Height
2.091 inches nominal
Actuator Style
round
Actuator Diameter
0.235 inches minimum and 0.245 inches maximum
Actuator Height
0.844 inches minimum and 0.906 inches maximum
Actuator Position-Action Relationship
up position maintained and down position maintained
Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Inclosure Type
fully inclosed
Nonpile-Up Contact Arrangement
1 pole, double throw, both positions maintained single switch unit
Contact Load Current Rating At Maximum Rated Voltage
80.000 amperes resistive dc and 30.000 amperes inductive dc and 7.000 amperes lamp dc and 30.000 amperes resistive ac and 20.000 amperes inductive ac and 7.500 amperes lamp ac
Test Data Document
"81349-mils3950 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
2 threaded stud

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5930-00-501-1772 No Name Available 10/30/1968

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4186300-083 Toggle Switch
4186300-83 Toggle Switch
8785K6 Toggle Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-00-989-4285?
The FSCG of the NSN 5930-00-989-4285 is 5930
Does the NSN 5930-00-989-4285 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509065
Does NSN 5930-00-989-4285 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-989-4285 contain precious materials?
Precious metal content is unknown
Does NSN 5930-00-989-4285 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-989-4285 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

BLUH1
5905-00-502-2027
Resistor,fixed,wire Wound,induct
BLUH1503J
5905-00-270-5687
Wire Wound Fixed Resistor
BLUHI
5905-00-147-1987
Composition Fixed Resistor
BLUHI100
5905-00-583-7765
Resistor,fixed,wire Wound,induct
BLUHI100000HMS
5905-00-101-7959
Wire Wound Fixed Resistor
BLUHI1500HMSP0RM5PCT
5905-00-270-7019
Wire Wound Fixed Resistor
BLUHI151J
5905-00-270-7019
Wire Wound Fixed Resistor
BLUHI20000
5905-00-068-6931
Wire Wound Fixed Resistor
BLUHI502J
5905-00-174-1977
Wire Wound Fixed Resistor
BLUHI50OHMSPORM1
5905-00-101-5419
Wire Wound Fixed Resistor
BLUHI602J
5905-00-843-3706
Resistor,fixed,wire Wound,induct
BLUHI75
5905-00-270-7018
Wire Wound Fixed Resistor
BLUHI75000HM
5905-00-655-1658
Resistor,fixed,wire Wound,induct
BLUL0
5905-00-283-5008
Resistor,fixed,wire Wound,induct
BLUL0-1
5905-00-843-6223
Resistor,fixed,wire Wound,induct